EAN Plus Series IP Box Camera Quick Installation Guide ** Lens not included.
EAN Plus Series 1. Overview The EAN Plus Series is a box type IP camera designed for indoor use. The series comes in four models: EAN3120 Plus / 3220 Plus / 3300 Plus. Model Name Megapixel WDR EAN3120 Plus 1.3 MP Yes EAN3220 Plus 2 MP Yes EAN3300 Plus 3 MP No 1 2 3 4 5 6 7 8 9 10 11 No. Item Name Descriptions 1 Memory Card Slot Insert a micro SD / SDHC card to store recording data. 2 Power LED Indicates the power is supplied. 3 DC 12V Port Connects to power.
EAN Plus Series System Requirements Before installing, please check that your computer meets the following system requirements. Operating System Microsoft Windows XP / Vista (32-bit) / 7 (32-bit) CPU Intel Core2 Duo 2 GHz or higher RAM 1 GB or more Additional HD space depends on required local storage of video files, 100 Mbps network card. Screen Resolution 1024 x 768 pixels or higher, 32-bit pixel color resolution Software DirectX 9.
EAN Plus Series 2. I/O Terminal Block The I/O terminal block, located on the rear panel of the camera, can be used to develop application for alarm input and output. 1 2 3 4 Pin Assignment No. Function No. Function 1 Alarm COM 3 Alarm Input 2 Alarm Output 4 Digital GND 3. Installation This installation guide provides the basic instructions on installing an EAN Plus box IP camera. For details, please refer to the User’s Manual in the software CD. 3.
EAN Plus Series If you are using a DC Auto Iris lens: 1. Remove the cover cap from the camera body. 2. Install the lens into the camera body. 3. Connect the DC cable to the DC Auto Iris Lens Connector. 4. When making final focus adjustment, place the ND filter (not supplied in the package) in front of the lens to force the lens iris to open, and then adjust the lens using the Focus / Zoom Screws. 5. Lock the Focus Screw and then remove the ND filter. C-Mount Lens: 1.
EAN Plus Series 4. Basic Connection 3 Audio 1 Ethernet (PoE) Power DC 12V Micro SD 3 Out Video Out 4 GND Reset COM Out In 2 In Alarm 5 1. Use a standard network cable to connect the camera to the network. 2. Connect the camera to power using one of the following methods: • Plugging the supplied power pigtail cable to the DC 12V port. • Using the PoE function and the power will be provided over the network cable. 3. Optionally connect the camera to a speaker and microphone.
EAN Plus Series 5. Accessing the Camera You have to assign an IP address for your camera to be accessible. To assign an IP address to the camera, use the IP Utility (IPU) software included in the software CD. Please connect the camera in the same LAN of your computer. 1. Install and then start the IPU program . The following dialog box appears. 2. Click Find Devices to search the cameras connected in the LAN. The default network values of the cameras will be displayed.
EAN Plus Series 5. To change the IP address, double-click the IP Address of the camera. Type a new IP address and then click Set IP Address to save the settings. You can also change the other settings by double-clicking the values. After configuring the values, click Save Configuration. Note: Most networks uses DHCP to assign IP address, if you are unsure of your network settings, please consult your network administrators for configuration details. 6.
EAN Plus Series 6. Network Connections You can use one of the methods below to connect the camera to the network. Router or LAN Connection This is the most common connection in which the IP camera is connected to a router and allows multiple users on and off site to see the IP camera on a LAN/WAN (Internet). The camera must be assigned an IP address that is compatible with its LAN. By setting up port forwarding on the router, you can remotely access the cameras from outside of the LAN via the Internet.
EAN Plus Series Direct High-Speed Connection In a Direct High-Speed Connection, the camera connects directly to a modem without the need for a router. You need to set the static or dynamic WAN IP address assigned by your ISP (Internet Service Provider) in the camera’s configuration web pages. To access the camera, just type “http://xxx”, where xxx is the IP address given by your ISP. If you have a dynamic IP address, this connection may require that you use DDNS for a reliable connection.
EAN Plus Series 7. Upgrading Firmware You can upgrade camera’s firmware using the IP Utility software included in the software CD. 1. Follow Step 1 to Step 4 in 5. Accessing the Camera to log in the camera. 2. Highlight the camera and then click Upgrade Firmware. A browsing window appears. 3. Select the firmware file (.evb) and then click Open. The IP Utility will automatically upgrade the firmware. The camera will reboot once the update is complete.
EverFocus Electronics Corp. EverFocus Taiwan: EverFocus Europe - Germany: 12F, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 2380 www.everfocus.com.tw marketing@everfocus.com.tw Albert-Einstein-Strasse 1, D-46446 Emmerich, Germany TEL: +49 2822 93940 FAX: +49 2822 939495 www.everfocus.de info@everfocus.