EKB500 UNIVERSAL KEYBOARD FW1.
SAFETY WARNINGS Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation. Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C. For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent. Install the device only in dry and dustproof surroundings. Protect the device against any liquid’s penetration. Avoid the penetration of any artefacts, e.g.
TABLE OF CONTENTS 1. Introduction 2. Features 3. Compatible devices 4. Delivery scope 5. Operating elements 6. Keyboard connections 7. Installation 7.1. General RS-485 bus installation 7.2. Connection of EPTZ 500 / 1000 / 3000 / 3500 7.3. Connection of EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 7.4. Connection of devices with Pelco-D/-P compatible protocol 7.5. Connection of EDSR / EDR series’ digital video recorders 7.6. Connection of several keyboards 7.7 Initial operation 8. Menu settings 8.1.
9.2.1.5. Preset tours 9.2.1.6. Alarm contact settings 9.2.2. EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation 9.2.3. Pelco-D / -P protocol-compatible devices’ operation 10. Technical data 4 30 31 32 33 36 EKB500_ma_en_rev1.
1. INTRODUCTION The EKB 500 universal keyboard was developed for both DVR remote control and telemetry control of speed domes and telemetry receivers. Ergonomic key alignment and the integrated jog/shuttle allow the convenient EverFocus DVR operation. 2 independent RS-485 interfaces enable installations with different telemetry protocols. 2. FEATURES 2 independent loop-through RS-485 ports, programmable with different protocols Protocol types: EverFocus, ED2200/2250 (Samsung Electr.
5. OPERATING ELEMENTS 1. DVR, MON, CAM Operation mode toggle key: DVR: DVR and DVR main monitor control MON: DVR call and matrix monitor control CAM: Camera control on call and matrix monitors, telemetry control switching 2. 3-axis joystick Joystick for speed dome and telemetry receiver control 3. LCD display Doublespaced LCD display for status message display 4. Jog / Shuttle Operating facility for playback and DVR menu control. 5. DVR control keys 6. Speed dome and telemetry receiver control keys 7.
6. KEYBOARD CONNECTORS RS-485 ports EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through). Pin assignment: Pin 1: 12 VDC Pin 3: RS-485 + Pin 6: RS-485 Pin 7: Ground Pin assignment RJ-45 connector connector box Delivery comprises a connector box for RS-485 and 12 VDC power supply connection enabling power supply connection either directly to the EKB 500 keyboard or through the connector box. RS-232 connector The 9-pin Sub-D connector is used for service purposes, e.g.
7. INSTALLATION 7.1. General RS-485 bus installation EKB 500 uses an RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences. The number of devices installed in one bus is limited to 32 (expandable through signal distributors), while max.
also be expanded by using these distributors, physically providing a new RS-485 bus with 1200 m cable length each at every distributor output. In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by using RS-485 distributors. Each distributor output physically provides one RS-485 bus which enables the additional connection of 31 further devices (the distributor output represents one bus participant itself).
7.2. EPTZ 500 / 1000 / 3000 / 3500 Speed dome camera connection Applied protocol type: EVF2 (standard) 7.3 ED-2200, ED-2250, Samsung SCC-641, SCC-643 , SCC-6405 connection Applied protocol type: A-Type 10 EKB500_ma_en_rev1.
7.4. Connection of Pelco-D / -P protocol-compatible devices Basic functions of speed domes and telemetry receivers compatible to Pelco-D / -P protocol can be controlled with the EKB 500 keyboard if a simplex RS-485 connection option is provided. For general connection, please refer to the chart illustrated above. Applied protocol type: Pelco-D / Pelco-P (in accordance with dome / receiver) ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1 at the keyboard, i.e.
7.5 EDSR / EDR series’ DVR connection The EKB 500 keyboard can control the following digital video recorders: EDSR series (despite EDSR100 19" model) EDR-410/810/920/1640 (MPEG-4 series) Installation with standard network cable: For short distances, EKB 500 can directly be connected using a standard network cable (patch cable, uncrossed!). Connection with EDA998 connector kit: Place the EDA998 connector kit at the RS-485 bus for easy DVR installation. 12 EKB500_ma_en_rev1.
System settings required for startup: DVR: MENU > RS232/RS485: RS485 BAUDRATE 9600 BPS > Baudrate must be the same as baudrate of the respective EKB 500 port (default setting for both keyboard and DVR is 9600) STOPBIT PARITY DATABIT RS232/RS485 ID > RS-485 address must correspond to DVR setting in EKB 500 menu 1 NONE 8 1 EKB-500: (for details, please refer to "8.
7.6. Connection of several keyboards If several keyboards (max. 8) are used in a system, the RS-485 bus has to be looped through from keyboard to keyboard. Using both RS-485 interfaces (port 1 and 2), the 2nd bus connection must be effected separately as illustrated above by means of EDA-998 connection kits. Power supply can be installed either directly at the keyboard or with the included connection box. 7.7. Startup After having finished the installation work, switch on the power.
8. MENU SETTINGS After electrical installation and startup, both the connected devices and the keyboard itself have to be set up. Hold the Shift key and press the Menu key to enter the keyboard menu. COM Port Setting Device Setting Use the joystick and the Enter key for menu navigation. Use the Esc key to leave the menu and return from submenus. The "<" icon at the end of the second line indicated further settings to be effected in this menu. Use the joystick to switch between the lines.
8.2. COM PORT SETTING - RS-485 interface setting Define telemetry protocol type and transmission rate in this menu. Port : _ ( 1 or 2 ) Input the port. MENÜ > COM PORT SETTING > Enter Select port 1 or 2 and confirm with Enter. Use the joystick to change the value. Selection: 1200, 2400, 4800, 9600 Baud. Press Enter to confirm the setting and Esc to cancel. BAUD : 9600 < [ ↑ ↓ ] to change The next menu is used for telemetry protocol setting. Use the joystick to change the value.
Setup of the RS-485 interface used for telemetry cameras, port 1 or 2. Enter any value for fixed cameras (numeric entry compulsory). Press Enter to confirm the setting and Esc to cancel. Setup of DVR and video input to which the camera is connected (requires a DVR installation in the „DVR Setting“ menu) Enter any value if no DVR is connected (numeric entry compulsory). Press Enter to confirm the setting and Esc to cancel. RS485 Connected to Port : _ [ 1 or 2 ] Video Connected to DVR : _ _ _ _ CH : _ _ 8.
8.3.3. DVR Setting Define the digital video recorders to be controlled by the keyboard in this menu. DVRs can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights can be set up, as only DVRs defined in this menu are available for access. DVR number, entry 1 ~ 9999 (independent of DVR RS-485 address). Press Enter to confirm the setting and Esc to cancel. DVR Name : _ _ _ _ Setup of the RS-485 interface to which the DVR is connected, port 1 or 2.
8.3.5. Monitor List & Delete This menu contains a list of all installed monitors as well as their settings. Furthermore, monitors can be deleted here. MENÜ > DEVICE SETTING > MONITOR LIST & DELETE > Enter Total 005 Monitors [ ENT ] to view list After pressing the Enter key, the first monitor is displayed. Displays: Name: DVR: CH: monitor number DVR to which the monitor is connected. DVR monitor output Name DVR CH 0012 0014 0002 < Del Monitor0000 [ ENT ] to confirm. Press Enter to delete the monitor.
8.3.7. Non-listed devices This function is currently not supported by RS-485 EEPBus. Use this menu to approve / disapprove the control of devices not defined in the menu. MENU > DEVICE SETTING > NON-LISTED-DEVICE > Enter Allow Operation w/o list [ ↑ ↓ ] to toggle Keep the default setting “No Operation w/o list” at any time, as this function is reserved for future applications only. No Operation w/o list [↑ ↓] to toggle 8.4. KEYBOARD SETTING This menu allows general keyboard and security settings. 8.4.
8.4.3. Lock password If this password is activated, the keyboard will lock after 30 seconds with no keyboard operation. Any keypress after locking will display a password inquiry at the LCD display. MENU > KEYBOARD SETTING > LOCK PASSWORD > Enter Enter an 8-character password. Press Enter to confirm. Input new Password : ________ Repeat the password. Press Enter to confirm. Repeat Password : ________ For activating the password protection, use the Joystick to select "YES" and press Enter to confirm.
8.4.6. Keypad test Use this menu for testing the keys’ functionality. MENU > KEYBOARD SETTING > KEYPAD TEST > Enter Press the keys to be checked. If the keys work correctly, the LCD display shows the key function in clear text. Press Esc to return to menu. [ _ _ _ _ _ _ _ _ _ _ ] Pressed [ Esc ] to exit 8.4.7. Jog & Shuttle test Use this menu for testing the jog/shuttle’s functionality. MENU > KEYBOARD SETTING > JOG&SHUTTLE TEST > Enter Move the shuttle (outer ring) towards the left and right end stops.
9. OPERATION 9.1. DVR operation EKB-500 provides a separate keypad for DVR control. The keys correspond to the EverFocus DVR front panel keys as regard to labeling and functionality. Besides these keys, further keys like MENU or Enter are required for different functions. NOTE: For browsing event list pages of DVR the shuttle ring switches with the first step (~20° movement). Moving the shuttle to the limit may block browsing pages for ~1 second.
9.1.2. DVR main functions The range of functions varies, depending on the DVR model and firmware version. The essential functions are described below; for further details please refer to the DVR manual. Please note that this description doesn’t provide a full function description of the EverFocus DVRs. Function Keys / operation DVR setup menu MENU Full screen Input channel number; key 1 is delayed for approx.
9.1.3. Main monitor (MAIN) operation in DVR mode The camera and monitor definition within the keyboard menu is irrelevant for the main monitor (MAIN) operation. As the operation is effected in DVR mode, CAM resp. MON switching is not necessary. Select the camera by entering the channel number (DVR video input) via the numeric keypad. Key 1 is delayed for approx. 1 second to enable input of channels 10~16.
9.2. SPEED DOME / TELEMETRY RECEIVER OPERATION / SETUP The operation of speed domes and telemetry receivers requires the setup of these devices in the EKB 500 menu. Settings within the following menus have to be adjusted: MENU > COM PORT SETTING for interface and protocol type setting MENU > DEVICE SETTING > CAMERA SETTING for speed dome / telemetry receiver connection settings EKB 500 is optimised for EverFocus EPTZ series speed dome control.
9.2.1.
9.2.1.1. EPTZ on-screen display Start EPTZ menu: Switch between the settings: Change the settings: Leave the menu: MENU Shift (hold) + JOYSTICK Shift (hold) + JOYSTICK Menu item EXIT > Enter or Clr (hold) + MENU 9.2.1.2.
Start preset Camera:0001 go to Position:___[1-192] POSITION > enter preset number > Enter 9.2.1.3. Home position The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation. Set (hold) + HOME > enter inactivity duration 1 ~ 999 minutes > Enter Back to home if no action for ___Minute Use the joystick to approach the requested position > Enter Move to home position [ENT] to confirm Use the JOYSTICK to activate the HOME function.
9.2.1.5. Preset tours The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each. For these tours, 2 operation modes are available: 1) Mode 1 (One way): after approaching all programmed presets, the tour restarts at the first programmed preset. Example: 1-2-3-4-5-6 > 1-2-3-4-5-6 > 1-2-3-4-5-.... 2) Mode 2 (back and forth) > after approaching all programmed presets, the speed dome returns to the presets in reverse order. Example: 1-2-3-4-5-6 > 5-4-3-2-1 > 2-3-4-5-6 > 5-.....
9.2.1.6. Alarm contact settings This function allows the EPTZ dome alarm contact assignment to presets or preset tours. Program alarm / preset / tour link F1 > enter alarm contact number 1 ~ 4 Link Alarm:_ [1-4] to Position [↑↓]:___ Use the JOYSTICK to switch between preset (position) and preset tour (tour) Link Alarm:_ [1-4] to Tour [↑↓]:___ Delete alarm / preset / tour link Clr + F1 > enter alarm contact number 1 ~ 4 > Enter Del AlarmLink:_[1-4] [ENT] to confirm 31 EKB500_ma_en_rev1.
9.2.2. EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation Required protocol type in "COM PORT SETTINGS": A-TYPE / SAMSUNG 9.2.2.1. On-screen display Start menu: Switch between the settings: Change the settings: Leave the menu: MENU Shift (hold) + JOYSTICK Shift (hold) + JOYSTICK Clr (hold) + MENU 9.2.2.2. Presets Preset parameters are defined in the dome menu. Please refer to the manual of the respective model.
9.2.2.4. Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Start A-B autopan A.Pan > enter pan speed 1~ 239 (any input, value is irrelevant due to speed being defined in the dome menu) > Enter Speed:___[1-239] [ENT] to start. 9.2.2.5. Preset tour / Pattern Define patterns (stored motion sequences of 30 seconds each) in the speed dome’s on-screen display.
9.2.3.2. Presets Save presets Camera:0001 Save to Position:___[1-192] Shift (hold) + POSITION > enter preset number > Enter Delete preset Camera:0001 Del Position:___ Clr (hold) + POSITION > enter preset number > Enter Start preset Camera:0001 go to Position:___[1-192] POSITION > enter preset number > Enter 9.2.3.3. Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model.
9.2.3.5. Pattern / Preset Tour Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Activate pattern Camera:0001 Run Tour:__[1-16] Tour > enter pattern number > Enter ATTENTION: At some third party domes with implemented Pelco-D the Preset tour starts with alternative command: POSITION > 98 > Enter 35 EKB500_ma_en_rev1.
10. TECHNICAL DATA Keys 48 Joystick 3-axis Display 2 lines with 20 characters each RS-485 2 independent RS-485 ports with 2 RJ-45 sockets each RS-232 1 x RS-232, Sub-D9 socket (service) RS-485 protocols EverFocus, ED2200/2250, Samsung Electr., Pelco-D, Pelco-P Power source 12 VDC +-10%, via power supply 230 VAC Power consumption 10 W max. Ambient temperature 0°C ~ 40°C, non-condensing Dimensions 360 (W) x 110 (H) x 200 (D) mm Weight 1,5 Kg 36 EKB500_ma_en_rev1.
EverFocus Electronics Corp. China Office: Room 609, Technology Trade Building, Shandgdi Information Industry Base, Haidian District, Beijing,China www.everfocus.com.cn Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan www.everfocus.com.tw USA Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. www.everfocus.com Japan Office: 1809 WBG MARIBU East 18F, 2-6 Nakase.Mihama-ku. Chiba city 261-7118, Japan www.everfocus.