EKB500 DVR and Telemetry Keyboard FW 1.
1 SAFETY WARNINGS • Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation. • Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C. • For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent. • Install the device only in dry and dustproof surroundings. Protect the device against any liquid’s penetration. • Avoid the penetration of any artefacts, e.g.
TABLE OF CONTENTS 1 2 3 4 5 6 7 8 9 SAFETY WARNINGS................................................................................................................... 2 INTRODUCTION ........................................................................................................................ 5 2.1 FEATURES ........................................................................................................................... 5 2.2 Changes from FIRMWARE 1.5 compared to former Versions ....
EKB500_ma_en_rev1.5_3.
2 INTRODUCTION The EKB 500 universal keyboard was developed for both DVR remote control and telemetry control of speed domes and telemetry receivers. Ergonomic key alignment and the integrated jog/shuttle allow the convenient EverFocus DVR operation. 2 independent RS-485 interfaces enable installations with different telemetry protocols. The new firmware 1.5 allows easier operation also in complex systems with several DVR and PTZ cameras. 2.
2.4 DELIVERY SCOPE 1 1 1 1 1 1 x x x x x x EKB-500 universal keyboard 12 VDC power supply RJ-45 connector, 120 Ohm terminated RS-485 connection kit incl. connector box and 1 m connection cable manual packaging 6 EKB500_ma_en_rev1.5_3.
3 OPERATING ELEMENTS 1. DVR, MON, CAM Operation mode toggle key: D D R DVVVR R: from firmware version 1.5 inactive, function reserved O M N M N: Selection monitor ON MO CCCAAAM M M: Selection camera 2. 3-axis JJJO O OYYYSSSTTTIIICCCKKK Joystick for speed dome and telemetry receiver control 3. LCD display Double-spaced LCD display for status message display 4. JJJO O G H U G /// SSSH OG HU UTTTTTTLLLEEE Operating facility for playback and DVR menu control. 5. DVR control keys 6.
4 KEYBOARD CONNECTORS 4.1 RS-485 PORTS EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through). Pin assignment: Pin Pin Pin Pin 1: 3: 6: 7: 12 VDC RS-485 + RS-485 Ground Pin assignment RJ-45 connector connector box Delivery comprises a connector box for RS-485 and 12 VDC power supply connection enabling power supply connection either directly to the EKB 500 keyboard or through the connector box. 4.
5 INSTALLATION 5.1 GENERAL RS-485 BUS INSTALLATION EKB 500 uses an RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences. The number of devices installed in one bus is limited to 32 (expandable through signal distributors), while max.
In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by using RS-485 distributors. Each distributor output physically provides one RS-485 bus which enables the additional connection of 31 further devices (the distributor output represents one bus participant itself). The maximum system expandability depends on the RS-485 address range of the installed devices. Attention: Most RS-485 signal distributors (e.g.
5.2 EPTZ 500 / 1000 / 3000 / 3500 SPEED DOME CAMERA CONNECTION Applied protocol type: EVF2 (standard) 5.3 ED-2200, ED-2250, SAMSUNG SCC-641, SCC-643 , SCC-6405 CONNECTION Applied protocol type: A-Type 11 EKB500_ma_en_rev1.5_3.
5.4 CONNECTION OF PELCO-D / -P PROTOCOL-COMPATIBLE DEVICES Basic functions of speed domes and telemetry receivers compatible to Pelco-D / -P protocol can be controlled with the EKB 500 keyboard if a simplex RS-485 connection option is provided. For general connection, please refer to the chart illustrated above. Applied protocol type: Pelco-D / Pelco-P (in accordance with dome / receiver) ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1 at the keyboard, i.e.
5.5 EVERFOCUS DVR CONNECTION The EKB 500 keyboard can control the following digital video recorders: EDSR series (despite EDSR100 19" model) EDR series (MPEG-4 series) EDVR series Paragon series Installation with standard network cable: For short distances, EKB 500 can directly be connected using a standard network cable (patch cable, uncrossed!). Connection with EDA998 connector kit: Place the EDA998 connector kit at the RS-485 bus for easy DVR installation. 13 EKB500_ma_en_rev1.5_3.
System settings required for start-up: DVR: MENU > RS232/RS485: RS485 BAUD RATE 9600 BPS STOP BIT PARITY DATA BIT RS232/RS485 ID 1 NONE 8 1 > > Baud rate must be the same as baud rate of the respective EKB 500 port (default setting or both keyboard and DVR is 9600) RS-485 address must correspond to DVR setting in EKB 500 menu EKB-500: (for details, please refer to "6.
5.6 CONNECTION OF SEVERAL KEYBOARDS If several keyboards (max. 8) are used in a system, the RS-485 bus has to be looped through from keyboard to keyboard. Using both RS-485 interfaces (port 1 and 2), the 2nd bus connection must be effected separately as illustrated above by means of EDA-998 connection kits. Power supply can be installed either directly at the keyboard or with the included connection box. 5.7 START-UP After having finished the installation work, switch on the power.
6 MENU SETTINGS After electrical installation and start-up, both the connected devices and the keyboard itself have to be set up. Hold the SSSH H M N U HIIIFFFTTT key and press the M MEEEN NU U key to enter the keyboard menu. COM Port Setting Device Setting Use the joystick and the EEEN N R NTTTEEER R key for menu navigation. Use the EEESSSCCC key to leave the menu and return from submenus. The "<" icon at the end of the second line indicated further settings to be effected in this menu.
6.2 COM PORT SETTING - RS-485 INTERFACE SETTING Define telemetry protocol type and transmission rate in this menu. Port : _ ( 1 or 2 ) Input the port. M M N U N R MEEEN NU U > COM PORT SETTING > EEEN NTTTEEER R Select port 1 or 2 and confirm with EEEN N R NTTTEEER R. Use the joystick to change the value. Selection: 1200, 2400, 4800, 9600 Baud. Press EEEN N R NTTTEEER R to confirm the setting and EEESSSCCC to cancel. BAUD : 9600 < [ ↑ ↓ ] to change The next menu is used for telemetry protocol setting.
Setup of the RS-485 interface connected to telemetry cameras, port 1 or 2, 0 for OFF (fixed camera). Enter 0 (off) for fixed cameras (numeric entry compulsory). Press Enter to confirm the setting and EEESSSCCC to cancel. RS485 Connected to Port : _ [ 0 (off) ] , 1, 2] If 1 or 2 was selected for PORT, the keyboard will automatically recognise this camera as a PTZ device in operation mode. Enter the RS485 Address of the PTZ camera (this menu item is skipped for fix cameras).
6.3.3 DVR Setting Define the digital video recorders to be controlled by the keyboard in this menu. DVRs can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights can be set up, as only DVRs defined in this menu are available for access. DVR number, entry 1 ~ 999 (independent of DVR RS-485 address). Press EEEN N R NTTTEEER R to confirm the setting and EEESSSCCC to cancel. Setup of the RS-485 interface to which the DVR is connected, port 1 or 2.
After pressing the EEEN N R NTTTEEER R key, the first monitor is displayed. Displays: Name: monitor number DVR: DVR to which the monitor is connected. CH: DVR monitor output Press EEEN R N R to delete the monitor. NTTTEEER R E T Press EEEN R T E N NTER again to delete the monitor and return to monitor list. Press EEESSSCCC to return to monitor list without deleting. Use the JJJO O OYYYSSSTTTIIICCCKKK Press EEESSSCCC to cancel. Name DVR Mon 005 004 02 < Del Monitor: 004 [ ENT ] to delete.
6.4 KEYBOARD SETTING This menu allows general keyboard and security settings. 6.4.1 Sub Keyboard Setting This menu provides settings for multiple keyboard installations. Keep the default value "0" for keyboard ID and number of sub keyboards for single keyboard installation. For multiple keyboard installations, the keyboards should be assigned to different IDs. Enter the keyboard ID 0~7 (one master keyboard with ID 0 required in system) and confirm with EEEN N R NTTTEEER R...
6.4.3 Lock password If this password is activated, the keyboard will lock after 30 seconds with no keyboard operation. Any key press after locking will display a password inquiry at the LCD display. M M N U N R MEEEN NU U > KEYBOARD SETTING > LOCK PASSWORD > EEEN NTTTEEER R Enter a max. 8-character password. Press EEEN N R NTTTEEER R to confirm. Input new Password : ________ Repeat the password. Press EEEN N R NTTTEEER R to confirm.
6.4.6 Keypad test Use this menu for testing the keys’ functionality. MENU > KEYBOARD SETTING > KEYPAD TEST > Enter Press the keys to be checked. If the keys work correctly, the LCD display shows the key function in clear text. Press Esc to return to menu. [ _ _ _ _ _ _ _ _ _ ] Pressed [ Esc ] to exit 6.4.7 Jog & Shuttle test Use this menu for testing the jog/shuttle’s functionality.
7 OPERATION 7.1 NEW EKB-500 OPERATION CONCEPT (FROM FIRMWARE 1.5) With firmware 1.5 the operation of keyboard will change. Overview of the changes: 1. Main- , Call- and Matrix monitors are operated with same input procedures. 2. Cameras are operated with same input procedure for all types of monitors. 3. The keyboard detects automatically, if a camera has PTZ function or not and signalize PTZ devices with "PTZ" in the LCD display. 4.
7.4 DVR PASSWORD INPUT If password protection is active in DVR, then the password is entered with the same procedure as described in ch. 7.3 CAMERA SELECTION: > [[[CCCAAAM M R N U M R M MEEER RAAA N NU UM MBBBEEER R]]] > CCCAAAM M or > CCCAAAM M N R M > [camera number] > EEEN NTTTEEER R or > SSSH H HIIIFFFTTT (hold) > [camera number] 7.5 DVR MAIN MONITOR OPERATION If a DVR main monitor is selected, the LCD - Display will show "DVR" in upper right corner. All DVR functions are active now as described below.
The essential functions are described below; for further details please refer to the DVR manual. Please note that this description doesn’t provide a full function description of the EverFocus DVRs. Function Keys / operation DVR setup menu M M E N U ME EN NU U Full screen Input channel number; key 1 1 1 is delayed for approx.
7.6 PTZ OPERATION / SETUP The operation of speed domes and telemetry receivers requires the setup of these devices in the EKB 500 menu. Settings within the following menus have to be adjusted: M M N U MEEEN NU U > COM PORT SETTING for interface and protocol type setting M E N U M E N U MENU > DEVICE SETTING > CAMERA SETTING for speed dome / telemetry receiver connection settings EKB 500 is optimised for EverFocus EPTZ series speed dome control.
7.6.
7.6.1.1 EPTZ on-screen display Start EPTZ menu: If DVR Main monitor is selected ("DVR" in LCD - display): CCCAAAM M M N U M (hold) + M MEEEN NU U If no DVR Main monitor is selected: M M N U M M N U MEEEN NU U or CCCAAAM M (hold) + M MEEEN NU U Switch between the settings: Change the settings: Leave the menu: JJJO O OYYYSSSTTTIIICCCKKK JJJO O OYYYSSSTTTIIICCCKKK Menu item EXIT > ENTER or CCCLLLR R M N U R (hold) + M MEEEN NU U 7.6.1.
Start preset Camera:0001 go to Position:___[1-192] PPPO R N N O O R NTTTEEER ON N > enter preset number > EEEN OSSSIIITTTIIIO 7.6.1.3 Home position The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation.
7.6.1.5 Preset tours The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each. For these tours, 2 operation modes are available: 1) Mode 1 (One way): after approaching all programmed presets, the tour restarts at the first programmed preset. Example: 1-2-3-4-5-6 > 1-2-3-4-5-6 > 1-2-3-4-5-.... 2) Mode 2 (back and forth) > after approaching all programmed presets, the speed dome returns to the presets in reverse order. Example: 1-2-3-4-5-6 > 5-4-3-2-1 > 2-3-4-5-6 > 5-.....
7.6.1.6 Alarm contact settings This function allows the EPTZ dome alarm contact assignment to presets or preset tours.
7.6.2 EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation Required protocol type in "COM PORT SETTINGS": A-TYPE / SAMSUNG 7.6.2.
7.6.2.4 Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Start A-B autopan AAA...PPPAAAN N ~ N > enter pan speed 111~ ~ 222333999 (any input, value is irrelevant due to speed being defined in the dome menu) > EEEN N R NTTTEEER R Speed:___[1-239] [ENT] to start. 7.6.2.
7.6.3.2 Presets Save presets Camera:0001 Save to Position:___[1-192] SSSH H O O N HIIIFFFTTT (hold) + PPPO OSSSIIITTTIIIO ON N > enter preset number > EEEN N R NTTTEEER R Delete preset Camera:0001 Del Position:___ CCCLLLR R O O N R (hold) + PPPO OSSSIIITTTIIIO ON N > enter preset number > EEEN N R NTTTEEER R Start preset Camera:0001 go to Position:___[1-192] PPPO O O N N R OSSSIIITTTIIIO ON N > enter preset number > EEEN NTTTEEER R 7.6.3.
7.6.3.5 Pattern / Preset Tour Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Activate pattern Camera:0001 Run Tour:__[1-16] TTTO O U R N R OU UR R > enter pattern number > EEEN NTTTEEER R ATTENTION: At some third party domes with implemented Pelco-D the Preset tour starts with alternative command: PPPO O O N N R OSSSIIITTTIIIO ON N > 999888 > EEEN NTTTEEER R 7.6.
8 SPECIFICATIONS Keys Joystick Display RS-485 RS-232 RS-485 protocols Power source Power consumption Ambient temperature Dimensions Weight 48 3-axis 2 lines with 20 characters each 2 independent RS-485 ports with 2 RJ-45 sockets each 1 x RS-232, Sub-D9 socket (service) EverFocus, ED2200/2250, Samsung Electr., Pelco-D, Pelco-P LG, Panasonic 12 VDC +-10%, via power supply 110/230 VAC 10 W max. 0°C ~ 40°C, non-condensing 360 (W) x 110 (H) x 200 (D) mm 1,5 Kg 37 EKB500_ma_en_rev1.5_3.
9 APPENDIX A: FACTORY SETTINGS PORT settings: Port 1: 9600 baud, EverFocus Port 2: 9600 baud, EverFocus DEVICE SETTINGS / DVR DVR1: 16Ch., port 1 Addr.1 DVR2: 16Ch., port 1 Addr.2 DVR3: 16Ch., port 1 Addr.3 DVR4: 16Ch., port 1 Addr.4 DVR5: 16Ch., port 1 Addr.5 DVR6: 16Ch., port 1 Addr.
Cam49: connected to DVR4, input1, PTZ-ID: OFF ....... Cam64: connected to DVR4, input16, PTZ-ID: OFF Cam65: connected to DVR5, input1, PTZ-ID: OFF ....... Cam80: connected to DVR5, input16, PTZ-ID: OFF Cam81: connected to DVR6, input1, PTZ-ID: OFF ....... Cam96: connected to DVR6, input16, PTZ-ID: OFF PASSWORDS: BUZZER: disabled ON 39 EKB500_ma_en_rev1.5_3.
EverFocus Electronics Corp. China Office: Room 609, Technology Trade Building, Shandgdi Information Industry Base, Haidian District, Beijing,China www.everfocus.com.cn Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan www.everfocus.com.tw USA Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. www.everfocus.com Japan Office: 1809 WBG MARIBU East 18F, 2-6 Nakase.Mihama-ku. Chiba city 261-7118, Japan www.everfocus.