EPTZ 100 Day / Night Speed Dome Camera INSTALLATION / OPERATION
1 SAFETY WARNINGS • Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation. • Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C. • For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent. • Install the device only in dry and dustproof surroundings. Protect the device against any liquid’s penetration. • Avoid the penetration of any artefacts, e.g.
TABLE OF CONTENTS SAFETY WARNINGS................................................................................................................ 2 INTRODUCTION ...................................................................................................................... 5 2.1 Features ............................................................................................................................. 5 2.2 Delivery scope.......................................................................
Remote switching of EPTZ 100 output relay ................................................................. 44 5.2.6 APPENDIX A: Basic Settings at EKB 500 keyboard.................................................................... 45 6.1 COM PORT SETTING - RS-485 interface setting.................................................................. 45 6.2 DEVICE SETTING > CAMERA ...........................................................................................
2 INTRODUCTION The mini PTZ speed dome EPTZ 100 provides ideal discreet surveillance for CCTV indoor applications. Engineered with the latest Digital Slow Shutter (DSS) x128 technology, EPTZ 100 can improve CCD sensitivity, producing quality images also under low light conditions. EPTZ 100 offers enhanced features such as privacy zones, noise reduction and 4 pattern tours with total 40 minutes duration. 2.1 2.2 FEATURES • Compact size design for discreet surveillance (only 114 mm / 4.
2.4 SPECIFICATIONS Camera Sensor: Effective pixels: Horizontal resolution: Sensitivity: Video output: S/N ratio: Sync. system: Electronic shutter: Digital Slow Shutter (DSS) White balance: Back light compensation: Gain: Flicker cancel: DNR Dynamic Noise Reduction: Day/night switching: Lens Zoom ratio: Focus length: Aperture: Viewing angle: Minimum object distance: Focusing method: 1/4” CCD SONY Super HAD 380.000 (NTSC), 440.000 (PAL) 520 TV lines (colour mode) 570 TV lines (b/w mode) 0,7 lux (F 1.
Alarm: Proportional pan speed: Privacy zones: Setup: Auto resume: Video output: Power Power source: Power consumption: Physical / environment Connectors: Ambient temperature: Humidity: Protection rating: Dimensions: Weight: Delivery scope: 3 inputs, 1 output, with tour / position auto triggering yes 4 zones, free adjustable multiline OSD setup menu after 1, 2, 3, 4, 5 or 10 min. no activity: go to BNC cable socket 24 V AC +/- 10% 19 W max. (with PTZ motors) 12 W max.
2.5 DIMENSIONS 2.5.1 Dimensions with ceiling mount adapter 202 54 170 114 80 115 ~150 2.5.2 Dimensions with recessed ceiling mount adapter 114 166 8 EPTZ100_ma_en_rev03.
2.5.3 Dimension EPTZ 100 with wall mount bracket EPTZ 100 WLM 225 270 2.5.4 Dimensions wall bracket EPTZ 100 WLM 169,5 140 240 120 140 80 240 60 80 9 EPTZ100_ma_en_rev03.
500 2.5.5 Dimension EPTZ 100 with ceiling pendant bracket EPTZ 100 CPM 120 2.5.6 Dimension ceiling pendant bracket EPTZ 100 CPM 300 72 80 80 100 10 EPTZ100_ma_en_rev03.
3 INSTALLATION 3.1 MECHANICAL 3.1.1 Ceiling mount The ceiling mount accessories are included in the EPTZ 100 package. 1. Use the drilling template to mark the drilling holes. 1 2) Click the connector board into the ceiling adapter. Follow the red arrow marks at board and ceiling adapter for correct position. 3 2 Connector board C ili d t 3) Mount the ceiling adapter and connector board to the ceiling. For the cables, use either the side outlet or a hole in the ceiling.
3.1.2 Recessed ceiling mount Recessed ceiling mount is possible at open ceilings. A metal ring has to be mounted at ceiling side. 1) Cut a 115mm / 4.6" hole into the ceiling. 2) Drill 3 screw holes for mounting in the ceiling Use the metal ring as template for drilling holes. 1 2 3) Plug the connector board to the dome module and latch it by turning clockwise. 4) Remove the clear dome cover and click the plastic cover ring at the dome cover with some pressure.
3.1.3 Wall mount Wall mount requires the optional bracket EPTZ 100 WLM. 1) Assemble the connector board to the bracket adapter by 3 M4 screws. Follow the red arrow marks at both board and ceiling adapter for correct position. 1 2) Remove the cable cover from the wall bracket. 2 3) Mount the bracket adapter with connector board to the bracket. 4) Mount the bracket to the wall. 5) Plug the dome module in the ceiling adapter.
3.1.4 Ceiling pendant mount Ceiling pendant mount requires the optional adaptor EPTZ 100 CLM. 1) Assemble the connector board to the bracket adapter by 3 M4 screws. Follow the red arrow marks at board and ceiling adapter for correct position. 1 2) Mount the bracket adapter with the connector board to the EPTZ 100 CLM. For wiring, use the upper hole or side outlet of the tube. 3) Mount the EPTZ 100 CLM to the ceiling. 4) Plug the dome module in the ceiling adapter.
3.2 ELECTRICAL 3.2.1 Video EPTZ 100 provides a composite 1 Vp-p video output PAL/NTSC (video system depending on ordered version) with a BNC cable socket. Cameras and video displaying or processing equipment (DVRs, switchers etc.) require cabling with 75 Ohm video cable, e.g. RG-59, RG-12, and suitable BNC plugs. Due to inappropriate absorbability, 50 Ohm coax cable (e.g. RG58), antenna cable and further types of coax cable are not suitable.
3.2.3 RS-485 EPTZ 100 uses RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences. Basically, the bus should be created by serial wiring, star wiring is only permitted using signal distributors. Maximum RS-485 bus cable length is 1200 m.
3.2.3.1 RS-485 installation with EKB 500 keyboard For connection to EKB 500 via RS-485, it is recommended to use the EKB 500 connector box. The drawing below shows an installation example. Please make sure that the wires are connected with correct polarity. Alternatively, it is possible to connect the RS-485 wire directly to the keyboard by using a standard RJ45 plug. The pin assignment is shown in the drawing below. Basic communication settings for EKB 500 are explained in Appendix A.
3.2.3.2 RS-485 installation with EverFocus DVR It is possible to control the EPTZ 100 speed dome by EverFocus DVR (except 1 Ch. models) via network. A combined local control by EKB 500 keyboard and remote (network) control by DVR is also possible. For a combined local and remote PTZ control, it is mandatory that DVR and speed dome are connected to the same RS-485 port of the EKB 500 keyboard. The RS-485 signal is looped through the DVR.
3.2.4 Alarm EPTZ 100 provides 3 alarm input contacts and 1alarm output relay. It is also possible to trigger the alarm output relay by EKB 500 keyboard command. For input contacts, use dry Normal Open (N.O.) contacts only. The maximum load of output relay contacts is 30 V AC/DC 0.5 A max. 19 EPTZ100_ma_en_rev03.
3.3 COMMUNICATION SETTINGS The setup for general RS-485 parameters - protocol type, RS-485 address and baud rate - is done by DIP switches, located at the top of the camera module. Correct settings are essential for communication with the dome controller. For correct communication, all 3 parameters - protocol, baud rate and RS-485 ID- have to comply with the PTZ controller settings. The 120 Ohm termination (DS3) is used at the last dome in the RS-485 bus for avoiding reflections in the RS-485 bus.
3.3.2 RS-485 ID (address) The RS-485 ID (address) setting is done by DIP switch DS2. The following table shows the switch positions for the possible addresses 1 ~ 255: 21 EPTZ100_ma_en_rev03.
EPTZ100_ma_en_rev03.
3.3.3 RS-485 bus termination The last device in an RS-485 bus should be terminated by 120Ohm resistor to avoid reflections on the bus (for details, please refer to chapter 3.2.3). The termination is done by DIP switch DS3. Termination ON 3.4 Termination OFF INITIAL START After finishing all installation steps, power on the EPTZ 100. At power-up, EPTZ 100 will perform an initialization. The communication settings will briefly appear on the screen.
4.1.
OSD Structure Part 2: MAIN MENU SYSTEM INFO DISPLAY CAMERA SCAN CONTROL CONTROL PRIVACY MASK AUTO RESUME AUTO RESUME ALARM POWER ON RESUME MODE INITIALIZE IMAGE FLIP TIME EXIT PRIVACY MASK MASK 1 MASK 1 MASK 2 POSITION MASK 3 ENABLE MASK 4 ALARM RELAY INPUT 1 INPUT 2 INPUT 3 OUTPUT INITIALIZE POWER ON RESET CAMERA DEFAULT FACTORY DEFAULT LENS REFRESH CAMERA REFRESH 25 EPTZ100_ma_en_rev03.
4.1.3 Main menu After opening OSD setup the MAIN menu is shown at the screen: MAIN MENU SYSTEM INFO DISPLAY CAMERA SCAN CONTROL PRIVACY MASK ALARM INITIALIZE EXIT Select a menu item with UP/DOWN, RIGHT will open submenu. NOTE: The OSD menu has a timeout function. After 2 minutes with no activity, the OSD menu will close automatically. 4.1.4 System info This menu shows the camera type, firmware version and communication settings. There are no editable items in this menu.
4.1.6 Camera This menu provides the camera video settings. CAMERA ZOOM SPEED Zoom speed setup in 8 possible levels: Level 1: slowest to Level 8: fastest ADVANCED SETTING Opens submenu for camera features (following chapter) RESCUE MODE Mode for recovering serial communication between speed dome and camera module. This mode is not needed for normal setup. Keep setting OFF. For details consult APPENDIX C: Troubleshooting BAUD RATE Baudrate display for RESCUE MODE.
some blue or reduce some red; if lighting is fluorescent or within white spectrum, try to either add some red or reduce some blue. Default values are 30 (for RED) and 40 (for BLUE); it is recommended not to set the values too far away from these two default values. BACKLIGHT Back light compensation improves the image quality in scenes with extreme light behind the object which usually washes out the image considerably.
EXPOSURE ZOOM POS INIT Defines a zoom position after powering up the camera, range is x1 ~ x10 LENS INIT Reset of the autofocus lens in case of malfunction END Return to CAMERA ADVANCED SETTING page BRIGHTNESS Image brightness setting, range 1~100 IRIS Mode of the lens iris: AUTO: automatic iris mode MANUAL: manual iris operation SHUTTER Electronic exposure control ESC: Electronic auto shutter, the shutter speed is automatically adapted to light conditions NOTE: This mode item is only available
SPECIAL Submenu for advanced camera functions: USER PRESET Not supported by EPTZ 100 PRIVACY Keep OFF setting, privacy mask setup is done in the PRIVACY MASK menu, available in the main menu DAY/NIGHT Modes of the day/night switching: B/W : black/white (night) mode, IR cut filter switched off COLOUR: colour (day) mode, IR cut filter switched on AUTO1: day/night switching with short delay time AUTO2: day/night switching with longer delay time SYNC: Synchronization mode, fixed at INTERNAL mode COMM ADJ
4.1.7 Scan This menu contains all setup options for automatic dome modes such as autopan, preset tours and pattern. SCAN AUTO PAN ALL PRESET GROUP SCAN TOUR SCAN PATROL PATTERN AUTO PAN PAN/TILT PAN ONLY This autopan mode performs pan and tilt movements between 2 points. The vertical movement will be processed in programmed speed from start / end point, the resulting movement is shown if the schema below: START Left autopan limit. Move to the position and press IRIS - to store the start point.
RETURN CIRCLE This autopan mode performs a continuous horizontal 360° movement. TILT LEVEL Adjust the vertical position of the camera, press IRIS - to store the vertical angle. SPEED Autopan speed, range from 2 (slowest) to 180 (fastest). RUN Autopan start (this function will close OSD menu). RETURN Return to AUTO PAN menu. RETURN ALL PRESET GROUP SCAN Return to AUTO PAN menu. Return to SCAN menu. This type of preset tour includes all programmed preset positions.
TOUR SCAN PATROL Combined preset tour with selected GROUP tours.
PATTERN A pattern is a programmed course of camera movement. EPTZ 100 can store 4 patterns with a maximum length of 10 minutes each. 1~4 RETURN Select a pattern for programming / checking. RECORD Start the movement programming with "Go To Preset 1". All manual movements / zoomings are recorded now. The TIMER in the display counts down the available time remaining in seconds. PREVIEW Shows the programmed pattern. Any pan / tilt command returns to PATTERN menu.
4.1.8 Control This menu provides settings for resume function after inactivity, power-up and special functions. AUTO RESUME OFF/ON > AUTO RESUME is the reaction of the dome after a defined time of inactivity (no operator action). ON: auto resume activated OFF: auto resume not active MODE Type of resume reaction: AP(P/T) A-B autopan (pan/tilt) AP(C) 360° autopan (circle) AP(P) A-B autopan (pan only) ALL PRESET preset tour with all presets GROUP1....
4.1.9 Privacy Mask EPTZ 100 allows for masking 4 different areas to protect private or confidential zones in the field of view.
4.1.10 Alarm In this menu, the alarm reactions for input contacts are defined. RELAY OFF/ON It is possible to switch the output relay remotely with this menu item for test purpose: ON: output relay switched OFF: output relay not active (off) INPUT1...3 PRESET x Assignment of the preset position which is linked to alarm input. Select preset position 1~32. OUTPUT OFF/ON ON: the camera will go to preset [assigned preset position in lines above] in case of alarm.
5 OPERATION WITH EKB 500 KEYBOARD The following chapter describes the EPTZ 100 operation with EKB 500 keyboard (with firmware 1.5 or higher). EPTZ 100 is optimized for protocol type EVF-2 of EKB 500 keyboard. Basic communication settings for EKB 500 are described in APPENDIX A. For further details, please refer to the EKB 500 user manual. The following operating elements are available for EPTZ 100 PTZ control: General key description: IIIR S R RIIIS S +++ /// ---::: F O C N F S U F N...::: F...
5.
5.1.
5.1.4 Preset tours EPTZ 100 provides 7 different preset tour modes. All tours are defined in OSD setup menu. 1. 2. 3. 4. 5. 6. 7. PATROL TOUR: ALL PRESET TOUR: GROUP 1 TOUR: GROUP 2 TOUR: GROUP 3 TOUR: GROUP 4 TOUR: TOUR SCAN: Preset tour with up to 16 selected presets. Preset tour with all available presets.
5.2 EKB 500 OPERATION WITH PELCO-D/P PROTOCOL NOTE: Not all EPTZ 100 functions are available in PELCO-D/P protocol. Operation for ssome functions is different to operation with EVERFOCUS protocol. 5.2.
5.2.3 Autopan The speed for autopan function is programmed in the OSD menu; the entered value for speed in EKB 500 will be ignored at start of autopan. Activate A-B autopan (pan/tilt between 2 points) A A P A N A...P PA AN N (Pelco-P only) Alternative: P P O S T O N E N T E R PO OS SIIIT TIIIO ON N > 999999 > E EN NT TE ER R 5.2.4 Preset tours EPTZ 100 provides 7 different preset tour modes. All tours are defined in the OSD setup menu.
5.2.6 Remote switching of EPTZ 100 output relay The EKB 500 keyboard provides the option to switch the output relay of EPTZ 100 On / Off.
6 APPENDIX A: BASIC SETTINGS AT EKB 500 KEYBOARD The following chapter describes the basic settings in the EKB 500 keyboard to establish communication with speed dome cameras. 6.1 COM PORT SETTING - RS-485 INTERFACE SETTING Telemetry protocol type and transmission rate are defined in this menu. Port : _ ( 1 or 2 ) Input the port. M M E N U E N T E R ME EN NU U > COM PORT SETTING > E EN NT TE ER R Select port 1 or 2 and confirm with E N T E E N T E R ENTER R. Use the JJJO to change the value.
7 APPENDIX B: BASIC SETTINGS AT EVERFOCUS DVR The following settings are required to establish RS-485 communication between DVR and speed dome: 7.1 EDR / EDVR / EDSR SERIES (EXCEPT EDSR100, EDSR100H) 1. CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel. 2.
8 APPENDIX C: TROUBLESHOOTING 8.1 GENERAL MALFUNCTION In case of drifted preset position or abnormal reaction of EPTZ 100 speed dome perform a reset of the dome, for the reset 3 options are possible: Option 1: Setup menu > INITIALIZE > POWER ON RESET Option 2: (GoTo) POSITION 80 Option 3: Power off dome for min. 5 seconds, then power on 8.
EverFocus Electronics Corp. China Subsidiary: Room 609, Technology Trade Building, Shandgdi Information Industry Base, Haidian District, Beijing,China www.everfocus.com.cn Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan www.everfocus.com.tw USA Subsidiary: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. www.everfocus.com Japan Subsidiary: 1809 WBG MARIBU East 18F, 2-6 Nakase.Mihama-ku. Chiba city 261-7118, Japan www.everfocus.