ES0802-41 8-port 10/100/1000M PoE+ Web Smart Gigabit Ethernet Switch User’s Manual Copyright © EverFocus Electronics Corp, Release Date: September, 2013 Notice: This content is subject to be changed without notice.
EVERFOCUS ELECTRONICS CORPORATION PoE Switch User’s Manual 2013 EverFocus Electronics Corp www.everfocus.com All rights reserved. No part of the contents of this manual may be reproduced or transmitted in any form or by any means without written permission of the Everfocus Electronics Corporation. Release Date: September, 2013 QuickTime is a registered trademark of the Apple Computer, Inc. Windows is a registered trademark of the Microsoft Corporation.
Safety Precautions FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions.
Table of Contents Table of Contents .................................................................................................. 5 1. Introduction .................................................................................................. 1 1.1 Product Overview................................................................................................. 1 1.2 Web Management Features ................................................................................ 1 1.3 Specifications .......
Ping....................................................................................................................... 30 3.3 Maintenance ...................................................................................................... 32 Warm Restart ....................................................................................................... 32 Factory Default ..................................................................................................... 32 Software upload ......
PoE Switch 1. Introduction 1.1 Product Overview This switch is a Web Smart Switch equipped with 8-ports 10/100/1000BaseT(X) with 8 PoE+ Ports. It is designed for easy installation and high performance in an environment where traffic is on the network and the number of users increased continuously. The compact rigid 19” rack-mount size is specifically designed for small to medium workgroups.
PoE Switch Statistics Overview Detailed Statistics LACP Status RSTP Status IGMP Status VeriPHY Ping Maintenance Warm Restart Factory Default Software Upload Configuration File Transfer Logout 1.3 Specifications Standard IEEE 802.3 10BaseT IEEE 802.3u 100BaseTX IEEE 802.3ab 1000BaseT IEEE 802.3af PoE IEEE 802.3at PoE+ IEEE 802.3z 1000BaseSX/LX IEEE 802.3x Full-duplex Flow Control IEEE 802.3ad Link Aggregation IEEE 802.1Q VLAN IEEE 802.1d Spanning tree protocol IEEE 802.
PoE Switch Port 1~8: Link/ Act, 1000M. Port 1~8: PoE Per Unit: Power Power Consumption: 130 Watts (Max), 30 Watts per port Power Input: 100~240V/AC, 50~60HZ Product Dimensions/ Weight: 266 × 160 × 44 mm (L × W ×H) / 1.6kg 1.5 Performance MAC Address & Multicast group: 8K Buffer Memory: 176 KB Jumbo Frames: 9.6K Transmission Method: Store and Forward 1.
PoE Switch 2. Hardware Description This part primarily presents hardware of this switch, physical dimensions and functional overview would be described. 2.1 Physical Dimensions/ Weight 266 × 160 × 44 mm (L × W ×H) / 1.6kg Front Panel The front Panel of the Web Smart Switch consists of 8 gigabit RJ-45 ports+2 gigabit SFP open slot. The LED Indicators are also located on the front panel.
PoE Switch Rear Panel The 3-pronged power plug is placed at the rear panel of the switch right side shown as below. Hardware Installation Set the switch on a large flat space with a power socket close by. The flat space should be clean, smooth, level and sturdy. Make sure there is enough clearance around the switch to allow attachment of cables, power cord and allow air circulation. The last, use twisted pair cable to connect this switch to your PC then user could start to operate the switch.
PoE Switch 3. Software Description This part instructs user how to set up and manage the switch through the web user interface. Please follow the description to understand the procedure. At the first, open the web browser, and go to 192.168.2.1 site then the user will see the login screen. Just clicks the Apply then the login process is completed and comes out the sign “Password successfully entered”. Figure 1-1 After the user login, the right side of website shows all functions as Fig. 1-2.
PoE Switch Figure 1-2 3.1 Configuration System System Configuration This page shows system configuration information. User can configure lots of information as Fig.
PoE Switch Figure 1-3 MAC Address: Displays the unique hardware address assigned by manufacturer (default). S/W Version: Displays the switch’s firmware version. H/W Version: Displays the switch’s Hardware version. DHCP Enabled: Click the box to enable DHCP Fallback IP address: Manually assign the IP address that the network is using. The default IP is 192.168.2.1 Fallback Subnet Mask: Assign the subnet mask to the IP address Fallback Gateway: Assign the network gateway for industrial switch.
PoE Switch manage the switch. By default, all ports on the switch are members of VLAN 1. However, if the management VLAN is changed, the management station must be attached to a port belonging to this VLAN. Name: Type in the new user name (The default value is ‘admin’). Password: Type in the new password (The default value is ‘admin’). SNMP Enabled: Enables or disables SNMP on the switch. Supports SNMP version 1and 2c management clients.
PoE Switch Figure 1-4-1 Figure 1-4-2 VLAN A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which would allow you to isolate network traffic, so only the members of the same VLAN will receive traffic from the ones of the same VLAN. Basically, creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch.
PoE Switch same switch physically. Port Segmentation (VLAN) Configuration VLAN ID: ID of configured VLAN (1-4096, no leading zeroes). VLAN Configuration List: Lists all the current VLAN groups created for this system. Up to 16 VLAN groups can be defined. VLAN 1 is the default untagged VLAN. Figure 1-5-1 VLAN Setup The switch supports up to 16 VLANs based on 802.1Q standard. From the VLAN Membership page you can create and delete VLANs, and change the VLAN port membership.
PoE Switch The 802.1Q Per Port Configuration page allows you to change the VLAN parameters for individual ports or trunks. You can configure VLAN behavior for specific interfaces, including the accepted frame types and default VLAN identifier (PVID). Each row of the table corresponds to one port or trunk; trunked ports cannot be configured individually; configure the trunk instead. Figure 1-5-3 Port/Trunk: The port number of the port or the ID of a trunk.
PoE Switch effect on ports that have Packet Type set to “Tagged Only.” (Default PVID: 1) It is not possible to remove a port from VLAN 1 unless its PVID has been changed to something other than 1. Outgoing packets are tagged unless the packet’s VLAN ID is the same as the PVID. When the PVID is set to “None,” all outgoing packets are tagged. ※Note: If you select “Tagged Only” mode for a port, we recommend setting the PVID to “None” as the standard configuration.
PoE Switch LACP Port Configuration Port: The port number. Enabled: Enables LACP on the associated port. Key Value: Configures a port's LACP administration key. The port administrative key must be set to the same value for ports that belong to the same link aggregation group (LAG). If this administrative key is not set when an LAG is formed (i.e., it has the null value of 0), this key will automatically be set to the same value as that used by the LAG. Figure 1-7 RSTP IEEE 802.
PoE Switch changing states (i.e., discarding to learning to forwarding). Number between 4 – 30 (default is 15). Force Version: Set and show the RSTP protocol to use. Normal - use RSTP, Compatible - compatible with STP. Figure 1-8-1 RSTP Port Configuration Port: The port ID. It cannot be changed. Aggregations mean any configured trunk group. Enabled: Click on the tick-box to enable/disable the RSTP protocol for the port.
PoE Switch Figure 1-8-2 Figure 1-8-3 Figure 1-8-4 16
PoE Switch IGMP Snooping IGMP Snooping is the process of listening to IGMP network traffic. IGMP Snooping, as implied by the name, is a feature that allows a layer 2 switch to “listen in” on the IGMP conversation between hosts and routers by processing the layer3 IGMP packets sent in a multicast network. When IGMP Snooping is enabled in a switch it analyzes all IGMP packets between hosts connected to the switch and multicast routers in the network.
PoE Switch on one switch port (or an entire VLAN) to a network monitoring connection on another switch port. This is commonly used for network appliances that require monitoring of network traffic, such as an intrusion-detection system. Mirroring Configuration Port to Mirror to: The port that will “duplicate” or “mirror” the traffic on the source port. Only incoming packets can be mirrored. Packets will be dropped when the available egress bandwidth is less than ingress bandwidth.
PoE Switch Figure 1-10-2 Quality of Service (QoS) In QoS Mode, select QoS Disabled, 802.1p, or DSCP to configure the related parameters. QoS Configuration Strict: Services the egress queues in sequential order, transmitting all traffic in the higher priority queues before servicing lower priority queues. WRR: Weighted Round-Robin shares bandwidth at the egress ports by using scheduling weights with default values of 1, 2, 4, 8 for queues 0 through 7, respectively. (This is the default selection.
PoE Switch Figure 1-11-1 QoS Mode: QoS Disabled When the QoS Mode is set to QoS Disabled, the following table is displayed. Figure 1-11-2 QoS Mode: 802.1p Packets are prioritized using the 802.1p field in the VLAN tag. This field is three bits long, representing the values 0 - 7. When the QoS Mode is set to 802.1p, the 802.1p Configuration table appears, allowing you to map each of the eight 802.1p values to a local priority queue (low, normal, medium or high). The default settings are shown below.
PoE Switch Figure 1-11-3 Figure 1-11-4 QoS Mode: DSCP DSCP: Packets are prioritized using the DSCP (Differentiated Services Code Point) value. The Differentiated Services Code Point (DSCP) is a six-bit field that is contained within an IP (TCP or UDP) header. The six bits allow the DSCP field to take any value in the range 0 - 63. When QoS Mode is set to DSCP, the DSCP Configuration table is displayed, allowing you to map each of the DSCP values to a hardware output queue (low, normal, medium or high).
PoE Switch DSCP Configuration table to a common priority queue. Use Custom if you want to set each value individually. When the QoS Mode is set to DSCP, the DSCP Configuration table is displayed as shown below. Figure 1-11-5 Figure 1-11-6 PoE (Power over Ethernet) Configuration Power over Ethernet (PoE) is an advanced technology providing a whole new application aspect for networking products.
PoE Switch Remote access and monitor the attached PD (Powered Device) status by using Enable/Disable function.
PoE Switch Figure 1-13-1 Enable Rate Limit: Click the check box to enable storm control. Rate (number of frames per second): The Rate field is set by a single drop-down list. The same threshold is applied to every port on the switch. When the threshold is exceeded, packets are dropped, irrespective of the flow-control settings. Web: Click PORTS, Storm Control. This page enables you to set the broadcast storm control parameters for every port on the switch. Figure 1-13-2 3.
PoE Switch Figure 2-1 Detailed Statics Figure 2-2 LACP Status LACP Aggregation Overview Figure 2-3-1 25
PoE Switch Port: The port number. Port Active: Shows if the port is a member of an active LACP group. Partner Port Number: A list of the ports attached at the remote end of this LAG link member. Operational Port Key: Current operational value of the key used by this LAG. LACP Port Status Figure 2-3-2 RSTP Status RSTP VLAN Bridge Overview Figure 2-4-1 Hello Time: Interval (in seconds) at which the root device transmits a configuration message.
PoE Switch because every device must receive information about topology changes before it starts to forward frames. In addition, each port needs time to listen for conflicting information that would make it return to a discarding state; otherwise, temporary data loops might result. Topology: Indicates if spanning tree topology is steady or undergoing reconfiguration. (The time required for reconfiguration is extremely short, so no values other that “steady” state are likely to be seen in this field.
PoE Switch IGMP Status IGMP Status IGMP Status shows the IGMP Snooping statistics for the whole switch. VLAN ID: VLAN ID number. Querier: Show whether Querying is enabled. Queries transmitted: Show the number of transmitted Query packets. Queries received: Show the number of received Query packets. v1 Reports: Show the number of received v1 Report packets. v2 Reports: Show the number of received v2 Report packets. v3 Reports: Show the number of received v2 Report packets.
PoE Switch Figure 2-6-1 Figure 2-6-2 Figure 2-6-3 29
PoE Switch Figure 2-6-4 Ping This command sends ICMP echo request packets to another node on the network. Ping Parameters Target IP Address: IP address of the host Count: Number of packets to send. (Range: 1-20) Time Out: setting the time period of host will be Ping Use the ping command to see if another site on the network can be reached. The following are some results of the ping command: Normal response: The normal response occurs in one to ten seconds, depending on network traffic.
PoE Switch Figure 2-7-1 Figure 2-7-2 31
PoE Switch Figure 2-7-3 3.3 Maintenance Warm Restart Press Yes button to restart the switch, the reset will be complete when the power lights stop blinking. Figure3-1 Factory Default This function is to force the switch back to the original factory settings. To reset the switch, select “Reset to Factory Defaults” from the drop-down list and click Apply.
PoE Switch Software upload Select “Upgrade Firmware” from the Tools drop-down list then click on the “Browse” button to select the firmware file. Click the APPLY button to upgrade the selected switch firmware file. User can download firmware files for user’s switch from the Support section of your local supplier. Figure 3-3 Configuration File Transfer Configuration file transfer allows you to save the switch’s current configuration or restore a previously saved configuration back to the device.
PoE Switch Figure 3-5 3.4 Reset button for the factory default setting Please take the following steps to reset the Web Smart Switch back to the original default: Step 1: Turn on the Web Smart Switch Step 2: Press and hold the reset button continuously for 5 seconds and release the reset button. Step 3: The switch will reboot for 20 seconds and the configuration of switch will back to the default setting.
EverFocus Electronics Corp. EverFocus Taiwan: 12F, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 2380 www.everfocus.com.tw marketing@everfocus.com.tw EverFocus China - Beijing: Room 609, Technology Trade Building, Shangdi Information Industry Base, Haidian District, Beijing 100085, China TEL: +86 10 6297 3336~39 FAX: +86 10 6297 1423 www.everfocus.com.cn marketing@everfocus.com.