Speed Dome EPTZ1000 USER MANUAL Date: Mar 2009
Table of Contents 1. EPTZ1000OVERVIEW...................................................... 1-3 1.1. Introduction .....................................................................................................1-3 1.2. Specifications ..................................................................................................1-5 1.3. Feature .............................................................................................................1-7 1.3.1. Hardware Overview ...........
. 3.1. 2.5.3. Corner mount .................................................................................2-22 2.5.4. Multi-Function Keyboard Controller ...........................................2-22 EPTZ1000CAMERA SETUP MENU ............................... 3-23 Structure of the Setup Menu.........................................................................3-23 3.1.1. 4. Camera Setup Menu .......................................................................
1. EPTZ1000OVERVIEW 1.1. Introduction EPTZ1000, an intelligent high-speed dome camera is ready to secure your property with its omni-directional and exact monitoring. An 18X optical and 12X digital zoom combining with a high-performance chip makes captured images clear and vivid. The other powerful camera functions this type of speed dome equips with: ¾ PAL / NTSC image format suppose. ¾ Auto and fast focus increases the searching speed and precision.
All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airports, stations, casinos, streets of cities, intelligent buildings, and etc.
1.2. Specifications Pickup Device 1/4'' SONY Type EXview HAD CCD Video Format NTSC or PAL Scanning System NTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution 480 TVL Sensitivity 0.7 Lux/F=1.4 S/N Ratio (AGC OFF) Over 50dB Electronic Shutter 1~1/10,000 (s) Digital Slow Shutter Yes Shutter Selection Yes Lens Type Zoom Ratio 18x optical zoom , f=4.1 mm (wide) to 73.8mm (tele) , F1.4 to F3.
Preset Positions Running to Position Speed 192 positions 1-239 grade available,0.1º/s - 360º/s Dwell Time at Preset Position 1~239 second available Tour 16 groups Tour Point per Group 16 preset positions Fan & Heater Fan & Heater auto starts Position Accuracy Alarm ±0.
1.3. Feature 1.3.1.
1.3.2. Base Board The base board that is on the bottom of the housing connects to power cable, video cable, control cable, alarm cable, fan and heater (fan and heater are for EPTZ1000 only). In order to connect to cables, the board needs to be taken off, and put back after finishing connecting to all cables. The connectors of cable names are marked on the board in white text. The details of the alarm connector (JP5) are shown on the APPENDIX A.
1 2 3 7 8 Adapter BNC 1.0Vpp ± 0.2V, 75 Ω Video Out RS485 Tx(+) RS485 Control Line RS485 Tx(-) Alarm 1 EPTZ1000DN/ EPTZ500DN Alarm 2 Alarm 3 4 ALARM INPUTS Alarm 4 GROUND ALARM OUTPUTS N.C. N.O. COM 1-9 8 6 POWER 24V AC / 3.5 A 7 5 24V AC 6 4 110V AC 5 3 1.4.
1.5. EPTZ1000 Quick Operation Guide EPTZ1000and EKB500 (Keyboard) can work together by using factory default setting. You just need to connect cables by following the steps: 1. Connect the RS485 cable to EPTZ1000and a Keyboard (EKB500). 2. Connect a video cable from EPTZ1000to a monitor. 3. Connect the power to the EPTZ1000and a Keyboard (EKB500) . After the speed dome finishes the self-test mode, you can start to operate the speed dome via the keyboard. To operate the EPTZ1000: UP IRIS + Focus F.
2. EPTZ1000INSTALLATION 2.1. Packing List There are 3 boxes that are housing, bulb and mechanical part with a camera module, one wall mount bracket, one power adapter and one accessory packet in the package.
- Video Cable A BNC cable is used for connecting a speed dome to a DVR or a monitor. An amplifier may be needed if the video cable is too long. - Control Cable Basically, EPTZ1000uses a differential pair to connect to other devices by cascading. A cable that has low signal decline can be used as a control cable. - Alarm Cable An alarm cable is not included in the packing list. A suitable wire can be used as an alarm cable. 2.3.
2.3.1. Address Setting The address code of the EPTZ1000should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary coded of the address, and there are 256 addresses can be selected (0 ~ 255, 28 = 256). It also means that there up to 256 dome cameras can cascade on the RS485 bus.
Switch Address ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7
Switch 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 ON 1 ON 1
2.3.2. Communication Protocol Setting The 1st, 2nd and 3rd bits of the SW2 are used to set communication protocol. The factory default protocol is EVF. SW2 PELCO-D PELCO-P TYPE-A ON 1 ON 1 ON 1 ON 1 ON 1 2 2 2 2 2 Protocol EVF - 1 3 3 3 3 3 4 4 4 4 4 Baud Rate 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 Maching Resistance 5 5 5 PAL / NTSC Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing.
2.3.4. Video Format Setting The 6th bits of the SW2 on the PCB board are used to set the video format. The default video format depends on the factory setting. Please do not change it. NTSC SW2 ON 1 ON 1 ON 1 2 3 4 4 5 5 6 6 7 7 8 8 4 3 3 2 2 Protocol PAL Baud Rate 5 6 PAL / NTSC 7 8 Maching Resistance Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing.
2.4. Rack and Speed Dome Installation 2.4.1. Installation Requirements 1. Installation should be handled by a qualified service agent and should comply with all local regulations. Service personnel should expect potential problems such as surface strength, surface material, falling objects, outer breaches, building vibration or other similar conditions. 2. Check for all necessary materials, and ensure if the selected installation location is suitable for the speed dome. 2.4.2.
2. Thread the cable through the hole in the wall mount bracket, and screw in 4 M8 nuts for mounting the bracket. 3. Take off the housing from the packing, and take off the baseboard (4 bolts on it.) inside the housing. Thread the cable through the top of the housing. Fix the housing on the wall mount bracket, and screw in 3 M5 bolts (Hex) on the top of the bracket with the attached Hex Allen wrench to fix the housing.
5. Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing, and twist the mechanical part clockwise a little bit in order to engage it with the base. Screw the two bolts on the base, and then connect and fix the connection bus to the PCB board on the mechanical part. Notice: The camera module on the mechanical part is very sensitive. Please be careful when installing this part. 6. Remove the lens protection cover before installing the bulb.
Notice: In order to protect the bulb from dirt and scrape, please put on the gloves before installing the bulb. 7. Turn on the power, and start to operate the EPTZ1000. Note: When turning on the power, the EPTZ1000 will enter self-inspection mode, and carry out a self-testing program. After finishing self-inspection, you can start to operate the EPTZ1000.
2.5. Separately Sold Accessories 2.5.1. Pole mount The pole mount is used for installing a speed dome on the ceiling indoors or outdoors. The extension poles are available for the pole mount. 2.5.2. Pole adapter The pole adapter is used for installing a wall mount bracket to a pole indoors or outdoors. 2.5.3. Corner mount The corner mounts are used for installing a wall mount bracket to a 270° corner of walls indoors or outdoors. 2.5.4.
3. EPTZ1000CAMERA SETUP MENU In this section, setup and operation guide of EPTZ1000will be introduced. There are 25 items of the setting menu. However, there is only one line on the line display, so using some combination keys to operate is necessary. 3.1. Structure of the Setup Menu Press MENU to enter camera setup menu. Press Shift + Joystick up/down to change subentries, and right/left to change the setting.
3.1.1. Camera Setup Menu Press MENU to enter camera setup menu. Press Shift + Joystick up/down to change subentries, and right/left to change the setting. 1. CAM ID: The name assigned to the camera. 2. DZOOM: Digital zoom enable or disable. ON: Enable a digital zoom. OFF: Disable a digital zoom. 3. FOCUS: Focus type, auto focus and manual focus are available. AUTO: Auto focus is enabled. MAN: Manual focus is enabled. ONE PUSH: Enable the one push trigger focus mode.
6. S.SHUTTER : (this function is only available for EPTZ1000) OFF: Disable auto slow shutter. AUTO: Auto Slow electrical shutter. In order to enhance the view in the low lux environment, slow shutter allows more light go through the shutter. 7. COLOR: Color display. ON: Enable a color display. OFF: Disable a color display, and show a B&W display. 8. DISPLAY: Display system information and status. ON: To display the system information and status on the screen.
12. AUTO FLIP: Flip the camera when it tilts to the 90° end. ON: Enable auto flip. OFF: Disable auto flip. 13. ALM-IN1: The status of input alarm 1. NIGHT N.O.: Dome turns to “Night mode” if external contact open. Dome turns to “Day mode” if external contact closed. NIGHT N.C.: Dome turns to “Night mode” if external contact closed. Dome turns to “Day mode” if external contact open. N.O.: Enable a normal open alarm input. N.C.: Enable a normal close alarm input. OFF: Disable alarm input. 14.
OFF: Disable alarm input. 17. ALM-IN PRIO: The priority of alarms. 1234: The alarm priority is 1>2>3>4. 2341: The alarm priority is 2>3>4>1. 3412: The alarm priority is 3>4>1>2. 4123: The alarm priority is 4>1>2>3. 18. ALM-OUT: Duration time of the alarm output. OFF: Disable alarm output. 3 / 5 / 10 / 20 / 30 / 60 SEC: The duration of the alarm output sustains in seconds. LATCH: The alarm output will not stop until there is any operation on keyboard. 19.
For Tour setting: Shift joystick to right and left (< >) for changing Set Numeral (T01A~T16A), then press “Enter” to confirm. Shift joystick to right and left for selecting PRE Numeral (position) from 01~99, then press “Enter” to confirm. Shift joystick up and down to adjust DWL (dwell) time from 0~99 sec, then press “Enter” to confirm. Shift joystick to right and left for adjusting speed (5~235, with an interval of 5), then press “Enter” to confirm.
Select this item, and then press “Enter” to load default setting. Press “Clr” + “Menu” whenever you want to quit menu setting. 25. EXIT : To exit. Select this item, and then press “Enter” to quit setting. Press “Clr” + “Menu” whenever you want to quit menu setting.
4. EPTZ1000FUNCTION SETUP AND OPERATION 4.1. Manual Control Mode ¾ Manual control: Shift Joystick Up/Down/Left/Right, and turn it Clockwise/Counterclockwise to control speed dome. Use the control keys which are Zoom, Focus and IRIS function keys on the keyboard to zoom In/Out, focus N (near)/F (Far), or IRIS +/-. Note: Zoom In/Out control keys will be disabled when entering to OSD menu mode.
to enter 360° auto pan speed (1~239). The camera will turn 360° automatically, but not tilt. 4.3. Position Setting ¾ Focus on a preset position: Press the number key, and then press Position to focus on the number of preset position; or you can press Position, then enter the preset position number, and then press Enter to focus on the number of preset position. ¾ Preset a position: Shift the Joystick to the position you would like to preset, and then press Shift + Position.
Dwell time: default is 2 sec; It can be changed by EVF Keyboard Set + A.Pan setting dwell time of A pos or B pos. 99 => Auto scan (360 degree) Default speed is 32. It can be changed by EVF Keyboard (Shift + A.Pan setting speed). For EPTZ1000, We can even set camera’s ICR Day/Night function with RS-485 command via keyboard. How to do this? Press Position + 88 to link to Day mode or Position + 89 to link to Night mode, “ICR AUTO” message will be shown on the right-bottom part of the screen.
¾ One-way tour Mode: Press Tour to enter the tour mode. The system will ask you to enter the tour number you would like to run, and starts the tour after pressing Enter. To preset a tour before running it is necessary. Preset a one-way tour: Press Set + Tour to preset a one-way tour. The system will ask you to enter preset position numbers (The positions need to be preset). After finish entering all positions, press Stop to quit, and then press Enter to save the tour.
If you set the position number to 99, the dome will do a 360 degree auto scan or AB two point pan if limit is ON. If you set the position number to 98, the dome will do a frame scan. ¾ Delete an alarm link: Press Clr + F1 to delete a link of alarm to position/tour. Note 1: After alarm output signal is terminated, the speed dome will resume action or return to its original position. Note 2: After powering on the speed dome, it will detect alarm status automatically. 4.6.
APPENDIX A: The Alarm I/O Connection There are 4 alarm inputs and 1 alarm output available. The alarm I/O connector that is marked as JP5 is a nine-pin connector. It is located on the PCB board of the housing. 1 ~ 9 RELAY JP5 RELAY JP5 Video + Video RS485 + RS485 - AC24 JP5 AC24 JP6 JP3 JP4 JP1 1 EPTZ1000 base board Pin # Function 1 Alarm Input 4 2 Ground 3 Alarm Input 3 4 Alarm Input 2 5 Ground 6 Alarm Input 1 7 Normal Open (N.O.) 8 Common (COM) 9 Normal Close (N.C.
EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886-2-26982334 FAX: +886-2-26982380 www.everfocus.com.tw Europe Office: Albert-Einstein-Strasse 1 D-46446 Emmerich, Germany TEL: 49-2822-9394-0 www.everfocus.de China Beijing Office: Room B-05D-1, KESHI PLAZA , Shangdi Information USA L.A. Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. TEL: +1-626-844-8888 FAX: +1-626-844-8838 www.everfocus.