Everglades AIRPUR/Fa. Klein Handelsweg 36 c 8251 JT DRONTEN Tel.: 0321 - 38 03 27 www.airpur.
SPECIFICATION Model no. Cooling capacity Heating capacity Power/Ampere consumption for cooling* Power/Ampere consumption for heating* Air volume (max. speed) Humidity removal capacity Maximum room size Power supply Compressor Refrigerant Refrigerant load* Fan speed Timer Thermostat Net Weight Dimension EV9037 9000 BTU/hr 2268 Kcal/hr 2637 watts 10000 BTU/hr 2520 Kcal/hr 2930 watts not applicable 830W/ 3.
BEFORE USE GENERAL SAFETY • • • Only use in the upright position on a flat level surface and at least 50cm from any objects (fig 1 & 4). Do not place objects on the unit or restrict air inlet / outlet (fig. 2). Closely supervise any children and pets when unit is in use. FIG.1 ELECTRICAL SAFETY • • For indoor use only. Switch off and unplug when not in use. • Do not use in humid or wet environments (fig 3) • Do not pull the unit along by the cord.
PARTS Back ty-® 1. 2. 3. Control Panel Air outlet Carrying handle 4. Caster Accessories 10. Inward adaptor - for insertion over hose and into back of the air conditioner. 11, Outward adaptor - for insertion over hose and into foam strip (or into hole in the wall/window). 12. Exhaust hose 13. Foam strip - for filling the open window space and with hole for connection to exhaust hose. 14. Foam strip - for filling the open window space 15. Round cap for filling the hole in wall/window. 16.
INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips Foam strips FIG.5 Offer foam strips to the window gap and cut to size if necessary. Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so that foam is held securely. This technique may also be used for sash windows. Note: Take care to maintain protection against intruders 2.
Mounting of the exhaust pipe • Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner • • Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 8 & 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible. FIG.8 JJ FIG.9 FIG.
Installation of the carbon filter 1. Remove the filter frame from the unit. Separate the filter fixer from the filter frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Fix the filter by reassembling the fixer onto the filter frame. 6. Re-fit the filter frame inside the unit.
OPERATION for mechanical type Cooling only model FIG. 12 Cooling & heating model FIG. 13 ® (J) o o 1. 2. 3. 4. 5. 6. Power indicator Fan operating indicator Cooling operating indicator 'Full water' indicator Thermostat Speed switch with options for - LOW FAN, HIGH FAN, LOW COOL, HIGH COOL 7. Timer (1-8 hours) as well as ON/OFF switch ooo Power indicator Fan operating indicator Cooling operating indicator 'Full water' indicator Heating operating indicator 6. Thermostat 7.
Cooling & heating models (not applicable) Turn the speed switch to select required setting: FAN, LOW COOL, HIGH COOL, LOW HEAT, HIGH HEAT HIGH HEAT L 0 W HEAT FAN '« LOW COOL HIGH COOL FIG.15 Setting temperature Turn the THERMOSTAT to regulate the temperature you desired. The cooling intensity is increasing clockwise.. Set timer Set the TIMER to the desired operating time (1 to 8 hours). When the set time has been reached, the machine will shut off automatically. Regulating air flow direction FIG.
OPERATION for electronic type Control panel 1. Automatic mode indicator 2. Cooling mode indicator 3. Fan mode indicator 4. Heating mode indicator (not applicable) 5. Compressor operation indicator 6. 'Set temperature' indicator 7. 'Room temperature' indicator 8. Timer operation indicator 9. Low ventilation indicator 10. High ventilation indicator 11. ON/OFF (power) button 12. Speed (ventilation)button 13. Timer button 14. Receiver for Remote Control FIG.17 15. 16. 17. 18.
Setting ventilation speed 1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator of high or low ventilation will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, the speed switch is invalid. Setting timer 1. Press TIMER button to set the operating hours you desired (1 to 12 hours, the timer indicator will light on).
DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. If the reservoir is full: a. For mechanical type, the compressor will stop, only the fan to circulate the air. The 'FULL WATER' indicator will light now to remind you. b. For electronic type, both of the compressor and motor will stop. The COMP. indicator will flash to show you. To make the cooling work again, please empty the water by one of the following ways: 1.
Please note 1. The drain must be at or below the outlet level. Original drain tube 2. Flashing comp / 'full water' indicator will not function in this mode of drainage. 3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm) Extended drain tube(OD: 18mm) FIG.23 Special caution for heating function ! While using the heating function, please note: FIG.24 12 1. Install the exhaust pipe well, in order to exhaust the cool air to outdoor.
MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet.
FAULT CHECK LIST The air conditioner does not run Is the air conditioner plugged in? Is there a power failure? Is the comp / 'full water' indicator flashing? Is the room temperature temperature? The machine seems to do little below the set Is there direct sunshine ? (Please put down the curtain.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing lots of heat? The machine seems to do nothing.
WARRANTY CONDITIONS Never move the device laying it on its side. Wait at least 2 hours after transportation before installing and turning on the machine, so the system gas/fluid will return into the compressor (this is very important for the preservation of your airco) You have 2 years of warranty from the manufacturer from date of purchase; but only in combination with a valid purchase invoice. Without purchase invoice there is no warranty.