Operation Manual

13
CORRECT PLACE FOR INSTALLATION
Product is designed in
accordance with the kitchen
counters supplied from
market. A safe distance
should be left between the
product and kitchen walls
and furniture.
If hood/aspirator will
be installed over your
appliance, obey to the
recommendation of hood/
aspirator manufacturer for
assembly height.
(min. 65 cm)
The gap that cooktop is to
be placed on the counter
should be cut in line with
cooktop installation
dimensions.
For installation of the product, the rules specied in local standards
related to electricity should be complied.
VENTILATION OF ROOM
The air needed for burning is received from room air and the gases
emitted are given directly in room. For safe operation of your product,
good room ventilation is a precondition. If no window or room to be
utilized for room ventilation is available, additional ventilation should
be installed. However, room has a door opening outside, it is no needed
to vent holes.
650 mm min.
Room Size Ventilating Opening
Smaller than 5m³ min. 100 cm²
Between 5 m³- 10 m³ min. 50 cm²
Bigger than 10m³ no need
In basement or cellar min. 65 cm²
GB