Section 2 Quick Setup Guide
Plasma Connections:
Front View of Plasma Torch and Work Clamp
GAS CONTROL TORCH WORK PIECE PILOT ARC
IMPORTANT:
Avoid ring the torch unless you are ready to cut. Excessive ring without cutting will wear the consumables
at an accelerated rate. Do not attempt to control the amperage with the foot pedal connected.
NOTICE:
For correct operation, use the correct consumable for the amperage selected amperage. Cutting nozzles
(tips) have different orice sizes. If you are operating on 120V, the maximum output of the cutter will only
be 25 amps. The stock consumable will not cut properly at 25 amps. See torch pages for alternative sizes
and amp range. Always maintain proper cutting air pressure (65-75 PSI). Use the Purge button to adjust the
cutting air pressure. Do not exceed 90 PSI supply pressure from the compressor to the regulator.