User Manual

Installation and Operation Guide
ROM II and ROM III
REQUIREMENT MAXIMUM MINIMUM
Bacterial Quality Potable Potable
Pressure 125 psig (860 kPa) 40 psig (280 kPa)
Temperature 100˚F (38˚C) 40˚F (4˚C)
Chlorine* 0 ppm (mg/L) 0 ppm (mg/L)
Production Flow Rate: 14.4 gpd (54 Lpd) @ 50 psig (340 kPa); 77˚ F (25˚ C)
Reject Flow Rate: 79.8 gpd (302 Lpd) @ 50 psig (340 kPa); 77˚ F (25˚ C)
*NOTE: Chlorine influent to Cartridge “B”. For Cold Water Use Only.
CONTAMINANT REDUCTION
Contaminant USEPA MCL ROM II Average % Reduction ROM III Average % Reduction
Total Dissolved Solids 187 94.6 94.6
Based on an RO Processor operating at 500 - 2000 mg/ L TDS; 40-70 psi; Neutral pH; Temperature 70 - 74˚ F; and a new Cartridge “B”.
Congratulations on the purchase of your new ROM II or ROM III
Reverse Osmosis Modular Drinking Water System. You and your
family are about to enjoy better tasting, healthier water than
you ever thought possible. The ROM II uses superior design and
contaminant reduction performance of the prefilter cartridge with
a quick-change reverse osmosis cartridge. The ROM III blends the
proven superior design and contaminant reduction performance
of Everpure’s ROM II Processor with a third cartridge for superior
performance in reducing volatile organic chemicals.
The result is the best available combination of technologies to
reduce aesthetic contaminants such as dirt, minerals, tastes and
odors; and health related contaminants such as sodium, heavy
metals and organics (VOC’s).
PARTS SUPPLIED
1. ROM II Head assembly / ROM III Head assembly
2. Cartridge "A" (S-101)
3. Cartridge "B" (TFC RO)
4. Cartridge "C" (VOC#1) (ROM III only)
5. EV312118 - Flow Restrictor Kit ROM II & III
6. EV310876 - Flush plug (1 w/ROM II, 2 w/ROM III)
7. EV305061 - Red 1/4" tubing
8. EV544600 - Blue 3/8" tubing
9. EV311659 - Reducing tee
10. EV311660 - T-link valve
11. EV311588 - Tank Kit
12. EV311652 - Faucet Kit
13. EV312731 - Fitting - Faucet
NOTE: Read and save this manual.
The pages that follow will help you install your system. The
ROM II or ROM III System supplied by Everpure contains a
processor, storage tank, air-gap faucet, and drain connector.
This instruction manual details the installation for a typical
residential reverse osmosis application, but the ROM II or ROM
III System may be used with alternate equipment, such as a water
cooler. Manuals supplied with other components should also be
consulted during the installation. Read all manuals first to get a
clear picture of your project before you begin.
Outlined on page 7 of this manual are several maintenance
procedures you will need to do to guarantee optimum
performance of your system. Page 9 contains a troubleshooting
guide to assist in diagnosing operational problems if they arise.
EV3080-17 Rev H DE09

Summary of content (12 pages)