Instructions / Assembly

1
FILTRATION & PROCESSING SOLUTIONS
INSURICE SYSTEMS INSTALLATION AND OPERATION GUIDE
Figure 1 Insurice
Single System
EVERPURE
®
INSURICE
®
FILTER SYSTEMS
NOTE: If the optional Everpure E-Series Filter is used,
install a manual shut-off valve leading to the system
for servicing.
4. Connect minimum 3/8” water line to inlet side of
Insurice system.
5. Connect tubing to flushing valve and run to drain.
NOTE: Some municipal plumbing codes and good
sanitary practices require an air gap at the drain
termination point.
6. Install the cartridge(s) into the Insurice System head(s)
following directions on the cartridge label or as shown in
the Cartridge Change Procedure section illustrations.
7. Turn on water to filter and check for leaks.
8. Flush the cartridge by running water through at full force
for five (5) minutes. This will set the filtering media and
purge air and fines, insuring maximum filter life.
9. After flushing, close the flushing valve, turn on power
to equipment and plug the LPA (if so equipped) into the
electrical outlet. See illustrations.
Check for compliance with state and local laws and
regulations. Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain
filterable cysts.
For installations in Massachusetts, the Commonwealth of
Massachusetts Plumbing Code 248 CMR shall be adhered to.
Consult your licensed plumber for installation of the system.
This system and its installation must comply with state and
local regulations.
SELECT A MOUNTING LOCATION
1. Give consideration to the weight of the unit when
operating (filled with water). Operating weights of the
Insurice Systems are:
Single System - 9 lbs (4.0 kg)
Twin System - 19 lbs (8.5 kg)
Triple System - 27 lbs (12 kg)
Quad System - 36 lbs (20 kg)
2. The location should allow for:
Minimum clearance of 2-1/2” (6.4 cm) under the
cartridge(s) so it can be lowered for removal and
replacement.
Adequate space for “in” and “out” water line connections.
Be near a drain for flushing and near a 110V outlet
if the accessory (sold separately) Everguard
TM
Low
Pressure Alarm is used. See Figures 1-4.
3. If possible, keep at least 6” (15 cm) available to the left
and the right of the Insurice System in the event poor
quality water conditions require the installation of the
optional Everpure K-Series Prefilter.
INSTALLATION
1. Use the predrilled mounting holes in the manifold
bracket as guides. Mark and drill anchor holes. Mount
securely.
See Figures 5-8.
2. Shut off power to machine.
3. Connect outlet port of Insurice system to equipment
served. Always use a NSF approved pipe dope or
plumber tape at all connections. Use a backup wrench
on all fittings while connecting to avoid excessive stress
on the system components.
Figure 2 Insurice
Twin System
Figure 3 Insurice
Triple System
Figure 4 Insurice
Quad System