User's Manual

EXTERNAL CONNECTIONS
The Control Unit incorporates a terminal block for
connection of hard-wired Zones (7-10), Siren or
Telephone Dialer unit. The connection terminal block
is located inside the Control Panel behind the front
cover.
To access the terminal block
Press , ,
this puts the system into Test Mode and prevents an
alarm occurring. Undo the two fixing screws on the
top edge of the Control Panel and open the front cover.
Before making any connections, ensure that the
memory jumper link P1 is in the ‘OFF’ position and then
remove the DC power jack and disconnect one of the
back-up batteries.
Hardwired zone and tamper switches should be Volt
free and Normally Closed, with the contacts opening in
order to initiate an alarm.
Note: Jumper link P51 should be fitted into the ON
position only if the external hardwired tamper circuit is
used, otherwise it must be in the OFF position.
After making your external connections reconnect the
power supply and Back-up Battery. Then close the
14
Control Panel cover and tighten the fixing screws on
the top edge of the Control Panel.
Switched
12Vdc output for
external Siren
(300mA max.)
Permanent
12Vdc power
supply output
(100mA max.)
(Volt-free)
Latching
relay contacts
Normally-Closed
Connections
(Using
Hardwired Zone
T3(Zone 9)
T1(Zone 7)
T2(Zone 8)
contacts)
T4(Zone 10)
GND
OUT
V+
C
N.O.
GND
N.C.
T4
T3
T1
T2
GND
GND
B+
TAMP
GND
external devices
Tamper circuit
connections for
pack 12Vdc
Battery power
input
Terminal Block Detail