User's Manual

Part-Arm 2 Setup
Exit Delay ON, 30s
Entry Delay Beep ON
Exit Delay Beep ON
Latchkey Setup
Status OFF
Selected User Setup OFF (all users)
Phone Numbers Not programmed
Home Control Setup
House Code A
Unit 1-8 Setup(Unit Code) 01-08
Alarm Trigger OFF
Answer Phone Setup
Status OFF
Greeting Message Not programmed
Digital Dialer Setup
Phone No. Not programmed
Unit ID No. Not programmed
Call Attempts 3
Open/Close by user OFF
RESET FACTORY DEFAULT
1. Press
,
User Password
to place the system in Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. Switch OFF the mains supply to the plug-in PSU
Adaptor and remove the plug from the DC power
socket in the Control Panel.
4. Remove either back-up battery and disconnect the
battery leads.
5. Set jumper link P1 to the ON position.
6. Reconnect the battery leads and replace the
back-up battery in position.
Reconnect the PSU Adaptor plug to the DC power
socket in the Control Panel and switch On the
supply to the PSU Adaptor.
7. As the Control Panel powers-up, ‘EEPROM RESET’
will be displayed while the factory default conditions
are restored to memory. Once the memory reset
has been completed ‘DISARM READY’ will be
displayed. The Control Panel will now be
reconfigured with all factory default settings.
8. Reset jumper link P1 into the OFF position.
9. Close the Control Panel cover and refit the fixing
screws.
17