User's Manual

NAME
Default setting: No name
Scroll through the menu until ‘3-1 Z01 Name’ is
displayed. The current setting will also be displayed.
To change the setting press .
Scroll through available options until the required
setting is displayed.
Press to save and exit, or
Press to exit without saving.
TYPE
Each alarm zone may be programmed to operate in
one of 5 different modes depending on the type of
alarm function it is required to perform. The following
alarm types are available:
Panic
- used to provide 24 hour monitoring of any emergency
being occurred. Activation of any Panic switch will
immediately initiate a Full Alarm condition.
Intruder
- provides standard intruder monitoring with normal
ARM and PART-ARM functions.
24 Hour Intruder
- used to provide 24 hour monitoring of areas requiring
continuous security protection even while the system
is Disarmed, (e.g. gun lockers). Activation of any
detector on a security zone will immediately initiate a
Full Alarm condition.
Fire
- use to provide 24 hour monitoring of any
Fire/Smoke detectors fitted to the system.
Activation of any detector will immediately initiate a
Full Alarm condition.
Test
- when the system is armed, any detector on the
zone will generate an entry in the Event-Log
without initiating an alarm condition.
24
Note: Panic, 24-hour Intruder and Fire modes all
operate on a 24 hour basis, (i.e. they are able to initiate
Full Alarm condition at any time irrespective of whether
the system is Armed or Disarmed).
Default setting: ‘Intruder
Scroll through the menu until ‘3-2 Z01 Type’ is
displayed. The current setting will also be displayed.
To change the setting press .
Scroll through available options until the required
setting is displayed.
Press to save and exit, or
Press to exit without saving.
FINAL EXIT SET
If enabled, triggering of any detector on the zone
during the exit-delay will cancel any remaining
exit-delay and cause the system to arm 5 seconds
later.
Default setting: OFF
Scroll through the menu until ‘3-3 Z01 Final Exit Set‘ is
displayed. The current setting will also be displayed.
To change the setting press .
Press to enable the zone’s Final Exit Set
facility, or
Press to disable the zone’s Final Exit Set
facility.
CHIME
This controls whether the Chime facility is available on
the zone.
Default setting: OFF
Scroll through the menu until ‘3-4 Z01 Chime’ is
displayed. The current setting will also be displayed.
To change the setting press .
Press to enable the zone’s Chime facility, or
Press to disable the zone’s Chime facility.