User's Manual

OPERATING INSTRUCTIONS
When leaving the premises, the system must be Armed.
However, before doing so, check that all windows are
closed and locked, all protected doors are closed and
PIR Detectors are not obstructed. Ensure that pets
are restricted to areas not protected by PIR Detectors.
The system has three arming modes, ARM, Part-Arm 1
and Part-Arm 2. The Part-Arm modes allow for
selected zones to be left in a Disarmed state while the
reminder of the system is Armed.
When the system is Armed (in any mode) the Control
Panel will display the arming mode and the status of the
Latch Key for a few seconds. If enabled, the system
Exit-Delay will start and be counted down on the display.
As the Exit-Delay expires the Control Panel will beep,
with the beep rate increasing in steps as the delay
expires. At the end of the Exit-Delay all active zones
be Armed. By this time the user must have left the
property and closed the final exit door.
If while the system is armed a detector on an active
zone is triggered, if enabled, the programmed
Entry-delay for that zone will start and be counted down
on the display. As the Entry-Delay expires the Control
Panel will beep, with the beep rate increasing in steps
as the delay expires. If the system has not been
disarmed when the Entry-Delay expires an alarm will
occur. If however, the Entry-Delay for the triggered
zone has been disabled an alarm will occur
immediately.
At the end of the programmed alarm duration the Siren
and Control Panel alarms will stop and the system will
automatically re-Arm.
ARM
The system can be set in ARM mode using either the
Remote Control or the Control Panel as follows:
Remote Control:
Press the ‘ARM’ button, ..
Control Panel:
Press the Arm button followed by the User
Password and then the Enter button:
36
User Password
By pressing , the programmed exit delay
will be overrided to 5 seconds.
PART-ARM 1
The system can be set in PART-Arm 1 mode using
either the Remote Control or the Control Panel as
follows:
Remote Control:
Press the ‘PART-ARM’ button, .
Control Panel:
User Password
By pressing , the programmed exit delay will
be overrided to 5 seconds.
PART-ARM 2
The system can be set in Part-Arm 2 mode using either
the Remote Control or the Control Panel as follows:
Remote Control:
Press the PART-ARM button twice, , .
Control Panel:
User Password
By pressing , the programmed exit delay will
be overrided to 5 seconds.
DISARM
The system can be Disarmed using either the Remote
Control or the Control Panel as follows:
Remote Control:
Press the ‘DISARM’ button, .
Control Panel:
User Password