User's Manual

1. Dial up the system and hang up after two rings.
2. Redial up the system within 20s as maximum (5s
as minimum), the system will pickup the phone
after 1 ring.
3. Enter the User Password as normal.
The following functions may be access via the remote.
The system will acknowledge each signal with a single
long beep.
Press to initiate ARM.
Press to initiate Part-Arm 1.
Press to initiate Part-Arm 2.
Press to Disarm the system.
Press to turn the Siren OFF
.
Press to turn the Siren ON.
Press to Listen-In via the Control Panel
Microphone.
Press to stop Listen-In
Note: Listen-in will be automatically cancelled after
5 minutes if not cancelled manually.
Press to interrogate the system status. The
status tone will be repeated at 2s intervals for 15s.
One beep ARM
Two beeps Part-Arm (1 or 2)
Three beeps Alarm triggered
Four beeps Fire triggered
One long beep Disarmed
Press to replay Answer-Phone messages.
While replaying a message, press for 2 seconds
to skip to the end of the message and hear the next
message.
Press to delete all Answer Phone messages.
Press to end the session and hang up the
Control Panel line.
CONNECTION TO HOME AUTOMATION
MODULES
Under the disarm mode, the on/off power of a series of
home automation receiver modules can be controlled
by the Control Panel as follows:
1. BH002/003: Press on the Control Panel’s
keypad and then key in the unit code (numbered
1-8) of home automation receiver modules to turn
on the power manually.
Press on the Control Panel’s keypad and
then key in the unit code (numbered 1-8) of home
automation receiver modules to turn off the power
manually.
2. BH004/006: Press on the Control Panel’s
keypad and then key in the unit code (numbered
1-8) of home automation receiver modules to turn
on and turn off the power manually.
Note: To turn on and turn off the lighting
fixture connected to BH004/006, simply using
as a toggle switch.
Note: Prior to adjusting the dimmer brightness, the
prerequisite is to turn on the lighting fixture.
Press on the Control Panel’s keypad and
then key in the unit code (numbered 1-8) of home
automation receiver modules to start dimmer cycle.
Press on the Control Panel’s keypad and
then key in the unit code (numbered 1-8) of home
automation receiver modules to select the dimmer
brightness you desire.
BATTERY MONITORING
All system devices continuously monitor their battery
condition. The Control Panel also monitors the battery
condition of all PIR and Magnetic detectors. If the
battery level of any device drops below acceptable
levels then its low battery indication will be activated.
In addition if any PIR or Magnetic Contact detector has
a low battery status it will be recorded by the Control
Panel and a message stored in the event log.
39