User's Manual

Full alarm condition occurs when system has
not been triggered by an intruder or is disarmed
1. Tamper switch activation
- check all detector battery covers to ensure
correctly fitted
- check Control Panel and Siren are securely
mounted to the wall and tamper switch is
closed
2. Panic alarm operated from a Remote Control or
Keypad
3. Jamming detection circuit operated
LED on remote control not illuminating, or is
dim when unit is operated
1. Ensure battery is connected with correct polarity
2. Ensure battery connections are good
3. Replace battery
PIR Detector false alarming
1. Ensure that the detector is not pointing at a
source of heat or a moving object
2. Ensure that the detector is not mounted above a
radiator or heater
3. Ensure that the detector is not facing a window
or in direct sunlight
4. Ensure that the detector is not in a draughty
area
5. Sensitivity detection set too high –reset to low
sensitivity detection
PIR Detector not detecting a person’s movement
1. Check battery connections are good.
2. Sensitivity detection set too low– reset to high
sensitivity detection.
3. Check that the detector is correctly set up.
4. Ensure DIP switches 1-4 of SW3 are correctly
set.
5. Ensure that detector is mounted the correct way
up.
(i.e. with detection window at the bottom)
6. Ensure that the detector is mounted at the
correct height, (i.e. 2-2.5m).
7. Allow up to three minutes for detector to
stabilize.
PIR Detector LED flashes on detection of
movement, (device in normal operation mode)
1. Low battery – replace battery.
Magnetic Contact Detector not working
1. Ensure batteries are connected with correct
polarity.
2. Ensure battery connections are good.
3. Ensure ‘House Code’ is correctly set.
4. Ensure DIP switches 9, 10 and 11 are set
correctly.
5. If no external contacts are connected ensure
jumper link fitted.
6. If external contacts are connected
a. Ensure jumper link removed
b. Check that all contacts are closed.
c. Check all contacts are wired in series.
Magnetic Contact Detector false alarming
1. Ensure that gap between magnet and detector
is less than 10mm.
2. Tamper switch below battery cover not
depressed – check battery cover is fitted
correctly and that fixing lugs are not broken.
LED on Magnetic Contact Detector illuminating
when door or window is opened.
1. Low battery – replace batteries.
DIGITAL DIALER TRANSMISSION
PROTOCOL
Contact ID Event Codes
Definition Code
Fire/Smoke Alarm 110
Panic Alarm 120
Intruder Alarm 130
24hr Intruder 133
System Tamper 137
AC Failure 301
System Low Battery 302
Sensor Tamper 383
Sensor Low Battery 384
Cancel/Abort Alarm 406
System Test 601
Open/Close by User 401
INH302WEVSP0E2A 43