6. Connect the power supply included
in the delivery to the central station
with reference to Fig. 2,
V+ cable with white lines
V- black cable.
7. If you also purchased an
emergency battery (12V / approx.
1.2Ah), connect this battery to the
plugs. Observe correct polarity! The
red plug connects to the positive
pole (+), and the black plug
connects to the negative pole (-).
8. The terminals POW and DIAL of
the central station can also be used
to connect the phone dialing
device S-126 for alarm transfer.
9. Use the jumper S1 to select the
alarm duration. This duration is
! 10 minutes with closed jumper
! 3 minutes with open jumper.
10. Now, connect the power supply to the mains supply.
11. A single "beep" tone signals that the central station is in standby mode, and the POWER LED
lights up.
12. Press the OFF key on the hand transmitter. Doing so, the central station automatically "learns"
your house code which will be confirmed by "beep beep".
Magnetic Contact Sensor HA 51M (Fig. 3)
13. The magnetic contact sensor is used to secure doors (Fig. 4), and
windows (Fig. 5). During mounting, make sure that the magnet is
attached to movable parts (window, door, etc.), whereas the sensor is
attached to fixed parts (border, frame, etc.).
14. Remove the cover of the sensor by sliding it
downwards (Fig. 6).
Fig. 2
Fig. 4 Fig. 5
Fig. 6