Table Of Contents
- Preface
- 1 Scope
- 2 Reference publications
- 3 Definitions and abbreviations
- 4 Design requirements
- 4.1 Supply fittings
- 4.2 Servicing
- 4.3 Installation
- 4.4 Threaded connections
- 4.5 Connections other than threaded connections
- 4.6 Accessible designs
- 4.7 Backflow prevention
- 4.8 Cover plates and escutcheons
- 4.9 Toxicity and lead content
- 4.10 Frost-proof faucets and hydrants
- 4.11 Showerheads, body sprays, and hand-held showers
- 4.12 Cross-flow
- 4.13 Fittings incorporating electrical features
- 4.14 Materials
- 4.15 Automatic compensating valve temperature control
- 4.16 Lawn faucets
- 4.17 Flexible water connectors
- 4.18 High-efficiency commercial pre-rinse spray valves
- 4.19 Household hot water dispensers with storage electrical heating systems
- 5 Performance requirements and test procedures
- 5.1 General
- 5.2 Coatings
- 5.3 Pressure and temperature
- 5.4 Flow rate
- 5.5 Operating requirements
- 5.6 Life cycle
- 5.7 Resistance to installation loading
- 5.8 Resistance to use loading
- 5.9 Backflow prevention
- 5.10 Lawn faucets
- 5.11 Alternative materials test
- 5.12 High-efficiency showerheads and hand-held showers
- 5.13 High-efficiency commercial pre-rinse spray valves
- 6 Markings, packaging, and installation instructions
- Annex A (informative) Unit conversion and rounding criteria
- Annex B (normative) Tests by fitting type
ASME A112.18.1-2018/CSA B125.1-18 Plumbing supply fittings
July 2018 © 2018 Canadian Standards Association
63
Table 3
Life cycle test
(See Clauses 5.6.1.1.1 and 5.6.3.1.2.)
Fitting Cycles
Bath or shower fitting*
250 000
Bidet fitting
50 000
Body spray, hand-held shower, or showerhead adjusting mechanism (flow
or function control)
10 000
Body spray or showerhead ball joint
10 000
Diverter (tub-to-shower, shower-to-shower, tub spout, bidet, shampoo,
shower-to-body spray, or in-line flow control device)
15 000
Laundry tub fitting
250 000
Lavatory or sink fitting*
500 000
Lawn or sediment faucet or hydrant
150 000
Low-pressure water dispenser
22 000
Low-pressure water dispenser swing spout
10 000
Pre-rinse spray valve
Commercial
250 000
Commercial high-efficiency
250 000
Metering faucet*
150 000
Self-closing faucet*
150 000
Side spray assembly, including the diverter (pullout spout handpiece
function control or multi-function aerator)
10 000
Supply stop†
2 000
Swing spout 50 000
* Includes electronic fittings.
† Supply stops integral with automatic compensating valves are not subject to the life cycle test.