Inverter Generator Owner’s Manual Guide D’Utilisation Manual del Propietario SF1000 SF2200 For product inquires or support, please visit www.evopower.co.uk or call our registered offices support number on 01646 66 38 48. Pour obtenir des renseignements sur les produits ou pour du soutien technique, visitez notre site à l’adresse www.evopower.co.uk (en anglais seulement) ou composez notre numéro sans frais 01646 66 38 48 Si tiene preguntas acerca de los productos o requiere de asistencia, visite www.
Congratulations on owning a Evopower inverter generator! WARNING This manual contains important instructions for operating this generator. For your safety, and the safety of others, be sure to read this manual thoroughly before operating the generator. Failure to properly follow all instructions and precautions can cause you and others to be seriously hurt or killed. Please use the spaces provided below to record important information about your generator.
PRODUCT REGISTRATION To register your product, please complete the information below and mail to the address at the end of the form or register online at www.Evopowergenerators.com. 18-digit serial number must be completed in order for warranty to be activated.
3 - DEMOGRAPHIC INFORMATION HOUSEHOLD INCOME: GENDER: MALE LESS THAN $15,000 $100,000 - $124,999 FEMALE $15,000 - $29,999 $125,000 - $149,999 $30,000 - $49,999 $150,000 - $174,999 MARITAL STATUS: $50,000 - $79,999 $175,000 - $199,999 MARRIED $80,000 - $99,999 $200,000 OR OVER SINGLE DATE OF BIRTH: / MM PRIMARY METHOD OF PURCHASING HOUSEHOLD ITEMS: / DD IN-STORE ONLINE YYYY TV INCLUDING YOURSELF, HOW MANY PEOPLE LIVE IN YOUR HOUSEHOLD: NUMBER OF CHILDREN UNDER 18 LIVING IN YOUR HOUSEHOL
CONTENTS IMPORTANT SAFETY RULES ............................................................................................ 1 ......................................................................................................................................... 1 Safety Messages Location of Important Labels GETTING STARTED ....................................................................................................................... 3 .........................................................
THIS PAGE INTENTIONALLY LEFT BLANK ii www.evopower.co.
SAVE THESE INSTRUCTIONS IMPORTANT SAFETY RULES WARNING ANYONE using or servicing this generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage.
Safety Messages Safety Messages Electric Shock Hazards WARNING Generators produce powerful voltage that can cause death or great physical harm. • NEVER touch bare wires or receptacles. • NEVER use generator with electrical cords that are worn, frayed, bare, or otherwise damaged. • NEVER operate generator in rain or snow, or when the generator is set on wet surface. • Keep the generator out of reach of children, pets, and untrained people.
Location of Important Labels Location of Important Labels Location of Important Labels Your generator has several labels which provide important safety and maintenance information. Samples of these labels are provided below. Should any of these labels become illegible or damaged, call 01646 663848 for replacements.
Location of Important Labels Location of Important Labels CAUTION Air intake located on bottom of inverter. DO NOT BLOCK ATTENTION Entrée d’air sur le bas de l’inverseur. MAINTENEZ LA ZONE CLAIRE. C 101588A CUIDADO El aire entra en el fondo de la unidad. NO BLOQUEE.
GETTING STARTED Use the information in this section to get your generator ready for operation. WARNING ANYONE using this generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. Package Checklist CAUTION Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury.
Grounding the Generator Grounding the Generator Grounding the Generator WARNING Generator must be grounded to prevent electrical shock from faulty appliances. • Before using generator, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of generator. The National Electric Code requires the generator to be connected to an earth ground.
COMPONENTS Use information provided in this section to become familiar with your generator’s components. CAUTION The information below is provided for reference only. Refer to “OPERATION” on page 11 for instructions on operating generator. Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury.
Front and Back View Front and Back View Front and Back View SF1000 Model 5 4 3 6 7 2 8 1 B F C A G J D E H A—Control Panel 1. Outlets 3. 125VAC outlet(s) (NEMA 5-15R [SF1000 model] and NEMA 5-20R [SF2200 model]) to connect 120V appliances to generator for power. DC outlet ranges from 12 to 18 volts and is unregulated. This outlet should not be used for battery charging.
Front and Back View Front and Back View SF2200 Model 5 6 8 4 7 3 1 B 2 F G C A J E D 7. I Engine Control Switch Turns the engine ON or OFF. 8. Efficiency Mode Switch When Efficiency Mode is ON, the engine speed will automatically adjust based on the connected load, resulting in better fuel consumption and less noise. In DC operation, set the Efficiency Mode Switch to the OFF position. B—Top Maintenance Cover Provides access to the engine spark plug.
THIS PAGE INTENTIONALLY LEFT BLANK 10 www.evopower.co.
OPERATION Generator Location When deciding on the location to place your generator, keep in mind the following safety rules: DANGER Depressed areas such as construction foundations, pools, or any low-lying areas, can cause carbon monoxide to accumulate. Inhalation of carbon monoxide can kill you in minutes. • NEVER use generator inside homes, garages, crawl spaces, sheds, or similar enclosed spaces. Use generator only outdoors and far away from windows, doors, and vents.
Starting Generator Starting Generator Starting Generator WARNING Before starting generator, be sure to thoroughly read all information provided in this Owner’s Manual. NOTICE It is very important to maintain the proper level of engine oil to keep the engine in good running condition. • Check engine oil level prior to each use. IMPORTANT! BEFORE STARTING GENERATOR, FILL WITH ENGINE OIL. Starting generator with appliances connected can cause permanent damage to appliances.
Starting Generator Starting Generator SF2200 Model Only: Depress the primer bulb 3 times to supply fuel to start the engine. FIGURE 11: Prime Engine NOTE: INITIAL START: Depress the primer bulb 30-50 times to prime the fuel lines. NOTE: 12. After starting, confirm the output ready indicator light is green and stays on. FIGURE 13: Output Ready Indicator Light (SF1000 model) 13. Allow the engine to run continuously and warm up before connecting any appliance.
AC Operation AC Operation AC Operation NOTE: DC power and AC power can be used at the same time. 1. Turn off and unplug all equipment to be plugged into the generator. 2. Start the generator (see “Starting Generator” on page 12). 3. Plug in the appliance and monitor the overload indicator light. If the overload indicator illuminates longer than 4 seconds, STOP THE ENGINE IMMEDIATELY. Do not restart generator until the reason for the overload or appliance short circuit is corrected.
Powering Appliances Powering Appliances Powering Appliances NOTE: In this manual, the term “appliance” refers to any electrical device that can be connected to generator for power. NOTICE NEVER start generator with electrical appliances plugged in and turned on. WARNING Faulty appliances and power cords can result in electrical shock. • Before attempting to power an appliance, be sure generator has been properly grounded, and that appliance and power cord are in good working order.
Appliance Wattage Information Appliance Wattage Information Appliance Typical Running Watts Iron 1000-1800 Microwave Oven 750-1100 Radio, Stereo 70-400 Refrigerator, Frost-free, 16 Cubic Feet* 725 Sump Pump, 1/2 hp* 2150 Sump Pump, 1/3 hp* 2300 Television • 19" 65-110 • 27" 113 • 36" 133 • 53"-61" Projection 170 • Flat Screen 120 Toaster 800-1400 Toaster Oven 1225 Vacuum Cleaner* 1000-1440 VCR/DVD 17-21 / 20-25 Washing Machine 350-500 Water Heater, 40 gal 4500-5500 Wate
MAINTENANCE Maintenance Schedule Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and inspection at the intervals shown in the Generator Maintenance Schedule (see Table 3). DANGER Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. WARNING Accidental starting of generator can cause severe injury or death.
Engine Oil Engine Oil Engine Oil 4. Remove the oil fill cap. NOTICE Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage engine and are not recommended. • Be sure to use engine oils specified under “Engine Oil Recommendations.” It is very important to maintain proper level of engine oil to keep engine in good running condition. • Check engine oil level prior to each use. Refill engine oil if oil level is low.
Engine Oil Engine Oil 7. Using a clean cloth, wipe around the drain plug area to remove any dirt and debris. 8. Insert the flexible hose directly into the oil fill hole and fill to the innermost thread of the crankcase. (SF2200 model illustrated) Changing Engine Oil WARNING Frequent or prolonged contact with engine oil may cause skin cancer. • Immediately after handling engine oil, thoroughly wash hands and any areas of skin exposed to engine oil, with soap and water.
Engine Oil Engine Oil 6. Place the oil pan, or other container suitable for holding engine oil, in front of the generator. CAUTION Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury. 9. Return the unit to the upright position. 10. Remove the oil drain pipe. 11. Using a clean cloth, wipe around the drain plug area to remove any dirt and debris. 12. Fill the oil fill container (included) with the appropriate amount and type of new (unused) oil.
Engine Fuel Engine Fuel 15. Reinstall the oil fill cap until fully tightened, center the choke, and attach the back maintenance cover. Engine Fuel Before each use, fill the fuel tank with recommended fuel. DO NOT OVERFILL. DANGER Fuel and fuel vapors are extremely flammable and explosive under certain conditions. FIGURE 28: Oil Fill Cap Installation NOTE: Dispose of used motor oil according to guidelines established by your local or state government.
Cleaning Fuel Strainer Cleaning Fuel Strainer 5. Ethanol (ethyl or grain alcohol) Gasoline containing more than 10% ethanol by volume may cause starting or performance problems. Gasoline containing ethanol may be marketed under the name "Gasohol". Methanol (methyl or wood alcohol) Gasoline containing methanol must contain co-solvents and corrosion inhibitors to protect fuel system.
Air Filter Maintenance Air Filter Maintenance Air Filter Maintenance NOTICE A dirty air filter will restrict air flow to the carburetor, which may cause poor engine performance or damage. Never run the generator without the air cleaner assembly properly attached. B A Clean the air cleaner filter every 50 hours of generator operation. If the generator is operated in extremely dusty areas, clean the air filter more frequently. WARNING Gasoline and flammable solvents can cause fire or explosion.
Cleaning Spark Arrestor Screen (SF2200 Model Only) Cleaning Spark Arrestor Screen (SF2200 Model Only) 6. Squeeze out excess oil. Cleaning Spark Arrestor Screen (SF2200 Model Only) WARNING Muffler reaches temperatures that can cause serious burns if touched. NEVER touch hot surfaces. FIGURE 37: Excess Oil Removal 7. Reinstall the air filter and air filter cover. The generator muffler is equipped with a spark arrestor screen, which must be cleaned according to the maintenance schedule (Table 3).
Spark Plug Service Spark Plug Service Spark Plug Service 6. To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. Using the spark plug wrench, loosen and remove the spark plug. WARNING If the engine has been running, the muffler will reach temperatures that could cause severe burns. DO NOT TOUCH.
Transporting Generator Transporting Generator Transporting Generator To prepare the generator for long-term storage:. DANGER WARNING Hot engine or exhaust system can cause serious burns or fires. Cool generator completely before transporting or storing. Do not leave generator inside vehicle during high temperatures. This could cause the fuel to vaporize and possibly explode. Do not overfill the tank before transporting.
TROUBLESHOOTING WARNING ANYONE using or servicing the generator must read, understand, and follow all safety and operation instructions provided in the product manual. Failure to closely follow these instructions can result in circumstances leading to death, serious injury, and property damage. DANGER Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
THIS PAGE INTENTIONALLY LEFT BLANK 28 www.evopower.co.
SPECIFICATIONS AND WIRING DIAGRAMS Model SF1000 SF2200 Length [in / mm] 18.1 / 459.7 21.3 / 541 Height [in / mm] 15.1 / 383.5 20.0 / 508 Width [in / mm] 9.6 / 243.8 11.4 / 289.6 30 / 13.6 58 / 26.
30 www.evopower.co.
Inverter Generator User's Manual DC breaker 10A AC _ DC12V Outlet AC + #16 blue DC winding primary low oil indicator light front panel assembly secondary N S inverter overload indicator light step motor/ fuel control M oil level sensor on / off switch white #16 black fuel economy switch output indicator light AC breaker 20A #14 black Duplex 5-20RA ground terminal #16 yellow / green WIRING DIAGRAMS WIRING DIAGRAMS SF2200 Model www.evopower.co.
THIS PAGE INTENTIONALLY LEFT BLANK 32 www.evopower.co.
WARRANTIES EVOPOWER CONSUMER LIMITED WARRANTY Evopower Inverter Generator Effective November 1, 2008 LIMITED WARRANTY Genpower cover any parts found by our own engineers to be defective in material or workmanship. This limited warranty covers the cost of the replacement parts and labour for defects. Transportation charges are the responsibility of the customer and generators must be returned to us to be assessed.
NORTHSHORE POWER SYSTEMS EMISSIONSNTROL WARRANTY THIS PAGE INTENTIONALLY LEFT BLANK 36 www.evopower.co.
INDEX A Air Filter Maintenance 23 Appliances powering 15 wattage information 15 B Breakers 8 C O Oil changing 19 Operation high altitude 14 preparing for 11 Outlets 8 S D Damage, Inspecting for 5 Draining Fuel 26 Safety Labels 3 Spark Arrestor Cleaning 24 Spark Plug Servicing 25 Specifications 29 Stopping Generator 14 Storage Recommendations 26 F T Checklist, Generator Contents 5 Fuel cap vent 12, 20 draining 26 oxygenated types 22 primer bulb 9 tank cap 9 valve 9, 12, 14 G Generator location 11
THIS PAGE INTENTIONALLY LEFT BLANK 38 www.evopower.co.
MAINTENANCE PARTS To order maintenance parts, visit www.evopower.co.uk or call Customer Hotline on 01646 66 38 48.
Genpower Ltd Unit 1, Dowty Park, Milford Haven, Pembrokeshire, SA73 P/N: 101435B January 2009 c 2009 Genpower Ltd 2RS The Evopower Trademark is used under license from Evopower International Inc. TEL 01646 663848 Evopower makes no representation or warranties with respect to this product www.evopower.co.