Instructions / Assembly

OPERATOR INSTRUCTIONS
Affinity 30G
Evo, Inc., 20560 SW 115th Ave., Tualatin, OR 97062 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | support@evoamerica.com
31
RECOGNIZING ABNORMAL GAS OPERATION
Any of the following are considered to be abnormal operation and may require servicing:
Excessive yellow tipping of the burner ame (See diagram above).
Sooting up of cooking utensils.
Burners not igniting properly.
Burners failing to remain alight.
Gas valves, which are dif cult to turn.
In case the appliance fails to operate correctly, contact the authorized service provider in your
area.
Right
Flame
Wrong
Flame
Dark BlueDark Blue
Light Blue Light Blue
Yellow Tip
Excessive
Yellow Tipping
Remove cooking surface
and drip pan to access valve
cover located just above
center control knob.
Checking Venturi Tubes:
A clogged venturi tube due to insects and insect nests in
the venturi tube may cause improper burner performance
and dif culty lighting your grill.
To check your venturi tubes:
Remove the cooking surface and drip pan to access the
valve cover located just above the center control knob.
Remove the cover and inspect the venturi for insects
and or insect nests.
Compressed air is the best method for removing these
obstructions.