Specifications

36 37
This represents the difference between R01 and stop cooling point.
R06 Start differential of heating
This represents the difference between R02 and start heating point.
R07 Stop differential of heating
This represents the difference between R02 and stop heating point.
R08 Min. set point in Cooling
Establishes the minimum limit for setting the Cooling set point
R09 Max. Cooling set point
Establishes the maximum limit for setting the Cooling set point
R10 Min. Heating set point
Establishes the minimum limit for setting the Heating set point
R11 Max. Heating set point
Establishes the maximum limit for setting the Heating set point
4.1 Installing the Wireless Antenna
The wireless antenna needs to be screwed into the antenna tting on the side of the heater
and should be pointing up. Do not overtighten the antenna. Failure to install this piece of
equipment will result in poor or non-existent communication between the wireless controller
and the heater.
Please check the wireless antenna has been installed.
4.2. Charging the battery
If the device displays a low battery signal, please do the following:
1. Either connect the charger to the controller directly or connect the charger to the
docking station and t the controller into the docking station.
2. Connect the charger to the power socket. When battery is charging, the battery icon
will ash.
3. When the controller shows full charge you may take the controller from the docking
station or disconnect from the charger.
1
2
Controller does not have to charge for a particular length of time- you can use the controller
when it is charging. If the battery power has been completely exhausted, then the device may
need to be charged for a few minute before the being able to be used.
When heat or other abnormal situations occur, please cut off the charger power immediately
and connect with after-sales service. If the battery has been fully charged, please cut off the
power, as the long-hour charging will easily destroy the charging IC and battery.
4. Wireless Controller Operation
Heating Cooling