NOTE: Approximately 75mm of the 
Workpiece Support Bar should slide into the base to 
provide positive location.
• Tighten the retaining screw.
• Repeat the above for the Left Hand side.
To remove a Workpiece Support Bar, simply loosen the 
relevant retaining screw and slide the Workpiece Support 
Bar from the machine. Store safely for future use.
THE REPEAT STOP (Fig. 42)
The use of the Repeat Stop can greatly aid the operator 
when conducting repetitive cutting operations. When 
many pieces of material all cut to the same length are 
required, use of the Repeat Stop can assist accuracy 
and efficiency.
Fitting the Repeat Stop
• Loosen the Repeat Stop thumb screws sufficiently 
to allow the arms of the Workpiece Support Bar to 
slide through the holes in the Repeat Stop.
• Position the Repeat Stop approximately half way 
along the Workpiece Support Bar, and tighten the 
thumb screws to minimize any movement.
• Attach the Workpiece Support Bar to the machine 
base as previously detailed.
NOTE: By loosening the thumb screws the Repeat 
Stop can be adjusted to the required distance from the 
saw blade for repetitive cutting operations etc. The 
Repeat Stop can be fitted to either of the Workpiece 
Support Bars but normally will be positioned to the 
Right Hand side of the blade. 
Fig.42
Repeat Stop in position