User's Manual User guide

Issue 4.3.C
IP Director Version 4.3 – User Manual – Part 3: Ingest and Play-Out
EVS Broadcast Equipment
174
DEFAULT START MODE PARAMETERS FOR
TRANSITIONS
To define the default start mode of elements added to a play-list
use the following dialogue settings:
Still Mode
The still mode setting determines if the play-list should stop on
the selected element and if it should stop where it stops and how
it should behave.
The options are:
Stop on first frame of current clip
Stop on last frame of previous clip
Stop on last frame of the previous clip, wait, then jump on
first
The play-list will stop on the last frame of the previous clip,
then jump on the first frame of the selected element after a
certain time which is defined in the value box.
Start Mode
If a Still mode is defined, one of the following start modes must
be defined on the selected element if ‘automatically’ was already
selected when a ‘Still mode’ is defined, it will be changed to the
‘Manual’ start mode as the modes are mutually exclusive.
Manually: the selected element must be started manually (by
a play or play var command) on the Play-List panel, keyboard
or ShuttlePRO controller.
On GPI : the selected element will be started when a GPI
trigger is received on the corresponding XT server (the one
the play-list is to be played on). The GPI number and its
trigger mode are defined in the general settings, GPI section.