Instruction Manual

*Please see separate Smart Relay manual for
complete instructions. The Smart Switch
Sub-Assembly is an accessory part of In-wall
Relay Switch and only functional when
connected with the Smart Relay.
Rev. A-032021 P/N SS01
Instruction
Manual
Smart Switch ×1
Instruction Manual ×1
Caution: Read this manual before attempting to
install the device! Using this product in a manner
other than intended voids your warranty. Further,
Focalcrest is NOT liable for any damage incurred with
the misuse of this product.
Warning: Turn OFF electrical power from the breaker
box or electrical service panel before installing or
servicing this product. Improper use or installation
can cause SERIOUS INJURY, DEATH, or LOSS/DAM-
AGE OF PROPERTY.
Caution: Use this product in an indoor environment.
Caution: All installations of this device should be
performed by a qualified or licensed electrician!
Caution: Product must be installed on a 10A line.
Installation Instructions
Product Introduction
Smart Switch Sub-Assembly is an optional
component of the In-Wall Relay Switch when they
are used together. The Smart Switch Sub-Assembly
is designed to allow mechanical switch panels to
work with switch commands from the zigbee
network. For example, after turning off the lights
with a mechanical switch panel, you can turn on the
lights through zigbee network commands.
One Smart Relay can be connected to one or a series
Smart Switch Sub-Assembly (multiple point control).
One Smart Switch Sub-Assembly can be connected
to two circuits of loads, each of which must use one
Smart Relay.
TECHNICAL SPECIFICATIONS
Model number SS01
Input Voltage AC 85V~245V
Max. Load Power
AC 110V/300W
AC 220V/600W
Min. Load Power No limit
Supported Switch Type Toggle, Momentary
Operating Temperature
0~40°C
(32°~104°F)
Relative Humidity 5~85% RH
Product Size (L*W*H)
33.5mm * 28.2mm * 17.3mm
(1.32in. x 1.11in. x 0.68in.)
Complete Accessories Include
Panel Connector Wire ×2
Fastening screws
Panel Connection port
Wire Connection port
SW1: External switch control for load
L : Power input for live wire
L1: Power output for live wire
L2: Power output for live wire
SW2: External switch control for load
NOTE:
‘SW1’ controls the ‘L1’
‘SW2’ controls the ‘L2’
With Smart Switch Sub-Assembly you can control Smart Relay
using traditional switch panel. Smart Switch Sub-Assembly
compatible with 1/2 gang switch panel, and two Smart Switch
Sub-Assemblies can be installed to support 3/4 gang switch
panel. The diagram to the right shows the connection of wires.
SW1
SW2
If the Smart Switch Sub-Assembly and Smart Relay
are connected correctly, it should look like diagram
below. For more instructions on how to install the
Smart Relay, please see the Smart Relay Manual.
LOAD 1 (Black) and LOAD2 (White) are installed using two different connection methods. Please choose the
appropriate installation method according to your actual installation environment.
In a single switch environment, please choose one of the installation methods to install according to your
actual installation environment.
NOTES FOR THE DIAGRAM:
1
Connect the wires to the switch panel
2
Overall Diagram
L - live wire
N - neutral wire
N
L OUT 1
L1 L2
L OUT 2
L
N
LOAD 2LOAD 1
SW1
SW2
In-Wall Relay Switch
Smart Switch Sub-Assembly