User Manual

Exalt Communications, Inc.
Exalt i-Series Installation and Management Guide
5000001 134
2007-06-25
Region 2 Specifics
The countries that are covered by this region are: Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Great Britain, Greece, Hungary,
Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Norway,
Poland, Portugal, Slovak Republic, Slovenia, Spain, Sweden, Netherlands, Switzerland,
and Turkey.
Note: The professional installer is responsible to ensure that RF output power is
properly adjusted to not exceed the regulatory limit.
Europe/ITU (ETSI and CE Mark)
The EX-2.4i family complies with ETS 300 328 for license-exempt use for most
countries recognizing ETSI or ITU band assignments. This band is not yet harmonized
for all countries recognizing ETSI or ITU band assignments. There is a +20dBm EIRP
limit applied to this band. Transmitter power must be adjusted accordingly with respect to
the RF cabling losses and antenna gains associated with each terminal.
The EX-5i family complies with ETS 301 893 for the 5.3 and 5.47 GHz bands for
license-exempt use for most countries recognizing ETSI or ITU band assignments. This
band is not yet harmonized for all countries recognizing ETSI or ITU band assignments
These bands require Dynamic Frequency Selection (DFS) and Transmitter Power Control
(TPC) for radar-detection and avoidance. There is a +30dBm EIRP limit applied to this
band. Transmitter power must be adjusted accordingly with respect to the RF cabling
losses and antenna gains associated with each terminal.
The EX-5i family complies with ETS 302 502 for the 5.8 GHz band. This band is not yet
harmonized for all countries recognizing ETSI or ITU band assignments. Consult the
individual country regulations or your Exalt Communications representative for details.
This band requires DFS and TPC for radar-detection and avoidance. There is a +33dBm
EIRP limit for use of the 10MHz BW setting (called 8MHz on GUI), and a +36dBm
EIRP limit for use of the 20MHz BW setting (called 16MHz on GUI).
All models comply with the requirements for CE Mark (EN 60950-1 and IEC 60950-1)
and EMC (EN 301 489-17). No substitutions shall be made, and all wiring and grounding
instructions contained in this manual must be followed to ensure safety in accordance to
the standards.