Record Keeping
After installation, record the following items for ongoing maintenance and future
troubleshooting. Keep a record for each end of the radio link and store a copy of these
records at the radio location, at the opposite end radio location, and a central record
storage location.
GPS coordinates for antenna locations at each site
Antenna heights above ground level (AGL), as mounted
Antenna model numbers, serial numbers, and specifications
Antenna polarization as mounted
Length/type of primary transmission lines at each site
Model number and serial number of RF lightning arrestors
Length/type of secondary transmission line(s)
Transmitter output power setting as installed at each site
RSL as measured after antenna alignment at each site
Designed RSL per original design at each site
RSL reading with far-end power off (from each end)
Spectrum analyzer plot with far end off at each site
Voltage standing wave ratio (VSWR)/return loss at radio’s antenna connector at each
site
Radio’s network management IP address at each site
Radio’s network management gateway address at each site
Radio’s operating frequency, bandwidth setting, and mode of operation
Optionally purchased extended warranty and/or emergency service contract details
In addition, certain information may be desired for central record-keeping only:
Security codes and login passwords (kept in a secure place)
Photographs of complete installation
End-user sign-off/acceptance documentation (if any)
Photo of rear panel label (part number, serial number, MAC address information)
Site access information phone numbers, access codes, directions