Warning: Consult a qualified electrician if uncertain about how to
properly ground the system and connect power.
Figure 16 DC connector
Once the wires are connected to the mating connector, do not connect to the radio. First
test the DC connection to the connector from the DC supply. Engage power on the DC
supply, and use a volt meter to verify proper voltage level and polarity.
Verify that the RF connector is properly terminated, as described in Terminating the RF
Connector on page 41. Disengage power once again on the DC source, and connect the
mating connector to the radio device. Engage power on the DC source. Verify radio is
active by observing LED activity. All LEDs flash during the initial power cycle to verify
that they are operational. Secure the DC connector using the integral captive screws at
each end. This prevents accidental disconnection.
See Power on page 41 regarding fusing, breakers, lightning protection, surge protection
and power conditioning. Follow these recommendations for a DC supply.
Reset to Critical Factory Settings
If necessary, the radio terminal may be reset to critical factory settings. This may be
necessary if the IP address and/or passwords for the system are not known. All other
configurations are left at their current settings. If a complete default factory configuration
is desired, load the Default Configuration File into the system, as described in System
Configuration Page on page 64.
The following parameters are configured after a reset to critical factory settings:
IP Address = 10.0.0.1
IP Mask = 255.0.0.0
IP Gateway = 0.0.0.0
Administration password = password
User password = password
Endpoint Identifier = Radio B (unless temporary hardware configuration key is
installed on a standard model, or the DIP switch is used on a -16 model)
To perform a reset to critical factory settings:
1. Remove power.
2. Remove connections to the ALARMS port.