Europe and ITU Country Compliance
All of these permitted devices must be professionally installed. They can only be used as a point-to-
point transmission device for fixed or temporary-fixed (non-mobile) installations.
The EX-2.4i product family operates under EN 300 328 rules as a license-exempt device. The 2.4 GHz
band is not yet harmonized in all countries recognizing ETSI or ITU band assignments. There is a
+20dBm EIRP limit applied to this band. Transmitter power must be adjusted accordingly with respect
to the RF cabling losses and antenna gains associated with each terminal.
The EX-4.9i devices are currently not permitted in any EU member or affiliate countries.
The EX-5i product family operates under EN 301 893 and EN 302 502 rules as a license-exempt
device.
The EX-5i product family complies with ETS 301 893 for the 5.3 and 5.47 GHz bands for license-
exempt use for most countries recognizing ETSI or ITU band assignments. This band is not yet
harmonized for all countries recognizing ETSI or ITU band assignments. These bands require
Dynamic Frequency Selection (DFS) and Transmitter Power Control (TPC) for radar-detection and
avoidance. There is a +30dBm EIRP limit applied to this band. Transmitter power must be adjusted
accordingly with respect to the RF cabling losses and antenna gains associated with each terminal.
The EX-5i product family complies with ETS 302 502 for the 5.8 GHz band. This band is not yet
harmonized for all countries recognizing ETSI or ITU band assignments. Consult the individual
country regulations or your Exalt Wireless representative for details. This band requires DFS and TPC
for radar-detection and avoidance. There is a +33dBm EIRP limit for use of the 10 MHz BW setting,
and a +36dBm EIRP limit for use of the 20 MHz BW setting. Some countries limit the EIRP to +5dBm
for all bandwidths in this band.
All models comply with the requirements for CE Mark (EN 60950-1 and IEC 60950-1) and EMC
(EN 301 489-17). No substitutions shall be made, and all wiring and grounding instructions contained
in this manual must be followed to ensure safety in accordance to the standards and local rules.
Note: Do not use external amplifiers to boost the power or overcome transmission system
losses, unless the specific amplifier/cable/antenna combination has expressly been authorized
by the specific country regulations. The output power must never exceed that specified in
Specifications
.