User's Manual
Table Of Contents
- EX-i Series (TDD)
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the i-Series Radios
- Initial Configuration and Back-to-Back Bench Test
- RF Output Power Setting
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Link Symmetry
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Command Line Interface (CLI)
- Telnet into the Command Line Interface (CLI)
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- Access Security Page
- System Configuration Page
- MHS Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- DS3 Configuration Page
- GPS Information Page
- Alarms Page
- MHS Status Page
- Performance Page
- Event Log Page
- User Throughput Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Ethernet Utilization Page
- Reboot Page
- Manual Page
- Specifications
- Interface Connections
- DIP Switch Settings (-16 Models Only)
- Antennas
- DC Coupler for Antenna Alignment
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for the European Union and ITU Countries
- EIRP Limits for Australia
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- END USER AGREEMENT
- Copyright Notices
- Index
Exalt Installation and Management Guide
EX-i Series (TDD) Digital Microwave Radios
206501-019 123
2016-05-24
EX-5i Series EIRP
Table 15 summarizes the maximum power by band and country for EX-5i Series radios.
5250–5350 MHz band
For EX-5i models within the 5250–5350 MHz band, the maximum EIRP is specified in Table 15. The
maximum output of the radio is +13 dBm.
P = ME – G + L
where:
France 20 dBm
Germany 20 dBm
Great Britain 20 dBm
Hungary 20 dBm
Iceland 20 dBm
Ireland 20 dBm
Italy 20 dBm
Liechtenstein 20 dBm
Lithuania 20 dBm
Malta 20 dBm
Netherlands 20 dBm
Norway 20 dBm
Poland 20 dBm
Portugal 20 dBm
Romania 20 dBm
Slovak Republic 20 dBm
Slovenia 20 dBm
Sweden 20 dBm
Switzerland 20 dBm
Turkey 20 dBm
P = Maximum transmitter output power of radio, in dBm.
ME = Maximum EIRP, as specified in Table 15.
G = Specified gain of antenna, in dBi, from 5250 to 5350 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and
the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as
specified or measured between 5250 and 5350 MHz.
Table 14 EU and ITU Country-Specific EIRP Levels for the EX-2.4i Series (Continued)