Installation Manual
Table Of Contents
- ExtendAir eMIMO Series Digital Microwave Radios Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the ExtendAir eMIMO Series Radios
- Initial Configuration and Back-to-Back Bench Test
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization (future feature)
- Radio Synchronization (future feature)
- Offset Timing
- Virtual Local Area Network (VLAN)
- Simple Network Management Protocol (SNMP) (future feature)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Telnet into the Command Line Interface (CLI) (future feature)
- Telnet
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- File Management Page
- System Configuration Page
- VLAN Settings Page
- Antenna Alignment Page
- Performance Page
- Metrics – Link Statistics and Radio Interface Statistics Page
- Reboot Page
- Manual Page
- Specifications
- Interface Connections
- Antennas
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Safety Notices
- Regulatory Notices
- Regulatory Compliance–TBD
- EIRP Limits for the United States and Canada
- EIRP Limits for Australia
- EIRP Limits for the European Union and ITU Countries
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- Exalt Limited Hardware Warranty Software License and RMA Procedures Agreement
- Copyright Notices
- Index
Exalt Installation and Management Guide
ExtendAir eMIMO Series Digital Microwave Radios
83 208363-001
2013-05-01
EIRP Limits for Australia
5470–5725 MHz Band
For ExtendAir eMIMO Series (regulatory model name/number eMIMO 100) models within the 5470–
5725 MHz band, the maximum EIRP allowed is 30 dBm. The maximum output power of the radio is
+21 dBm.
P = 30 – G + L
where:
5725–5850 MHz Band
For ExtendAir eMIMO Series (regulatory model name/number eMIMO 100) models within the 5725–
5850 MHz band, the maximum EIRP allowed is 36 dBm. The maximum output power of the radio is
+28 dBm.
P = 36 – G + L
where:
Note: The professional installer is responsible to ensure that RF output power is properly
adjusted to not exceed the regulatory limit.
Note: Australian regulations have a no-transmit band from 5600–5650 MHz, adjust the
transmitter to avoid this range.
P = Maximum transmitter output power of radio, in dBm.
G = Specified gain of antenna, in dBi, from 5470 to 5725 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and the
antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified
or measured between 5470 and 5725 MHz.
P = Maximum transmitter output power of radio, in dBm.
G = Specified gain of antenna, in dBi, from 5725 to 5850 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and the
antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified