4. Remove the lift and lock the adjuster screw in place
by turning the lock nut A clockwise (tighten).
3. From the underside of the table, adjust the 4 phillips
head screws in the corners A - up or down until the
plate is flat and level with the table surface.
2. Use a straightedge to test the plate for level with the
table top.
1. Place the router lift into the opening in the table.
Note: Model #40-070 for 40-100C Cast-iron table shown. The following steps apply to all 3 table options.
5. After the four corners are set, proceed to set the
remaining 6 leveler screws and lock them in place.
Note: While tightening the lock nut, make sure that the
adjuster screw does not turn. Confirm by re-checking the
leveling of the lift and table surface.
A
17