SETTING-UP
CONNECTION OF THE FLEXIBLE HOSE TO THE GUN
Connect the high pressure flexible hose
(F1)
to the pump
(F2)
and to the gun
(F3)
ensuring to tighten the fittings (the use of
two wrenches is suggested)
.
NEVER use sealants on fittings’ threads
.
It is ADVISED to mount a high pressure manometer at the
pump outlet (see on page “Accessories”) to read the product
pressure
.
It is recommended to use the hose provided with the standard
kit (ref. 18036).
NEVER use a damaged or a repaired flexible hose.
CHECK ON POWER SUPPLY
Make sure that the electrical system is earthed and
complies with regulations.
Check the mains voltage corresponds to the equipment’s
rating.
The supply cable is provided without plug.
Use a plug which guarantees the plant earthing.
Only a technician or a skilled person should perform the
connection of the plug to the electric cable.
Should anyone use an extension cable between
the tooling and the socket, it must have the same
characteristics as the cable supplied (minimum
diameter of the wire 2.5 mm
2
) with a maximum
length of 50 mt. Higher lengths and lower diame-
ters can provoke excessive voltage falls and also
an anomalous working of the equipment
F2
F1
F3