Technical data
15
NEW EXCALIBUR
English
G
• Remove the suction pipe and take away the solvent tank.
• Point the gun into the solvent tank and press the trigger so
as to recover the residual solvent.
• As the pump idles, press the “OFF” (0) switch to stop the
tooling.
• Now the machine is ready. Should you use water paints,
besides the solvent wash, a wash with soapy and then clean
water is suggested.
• Insert the gun trigger lock and assemble the nozzle.
PREPARATION OF THE PAINT
• Make sure the product is suitable to be used with a spray gun.
• Mix and filter the product before using it. For filtration, use
CLOSE-MESH (ref. 214) and LARGE-MESH (ref.215) LA-
RIUS METEX braids.
Absolutely avoid to spray solvents indoors. In
addition, it is recommended to keep away from
the pump in order to avoid the contact between
the solvent fumes and the electric motor.
Never use products containing halogen hydrocarbons (as methy-
lene chloride). If these products come into contact with aluminium
parts of the equipment, can provoke dangerous chemical reactions
with risk of explosion.
Make sure the product to be used is compatible
with the materials employed for manufacturing the
equipment (stainless steel and aluminium).
Because of that, please contact the supplier of the
product.
• Point the gun (F3) into a container (F8) keeping the trigger
pressed (so as to drain the oil inside) till a clean solvent comes
out. Now, release the trigger.
WORKING
START OF THE PAINTING OPERATIONS
• Use the tooling after performing all the SETTING UP ope-
rations above described.
• Dip the suction pipe (G1) into the product tank.
• Open the recirculating-safety valve (G2) (turn clockwise so
as the pin slides on the cam track).
OPEN
It re-circulates back into
the tank without spraying
CLOSED
It sprays out of the spray
gun
F3
F8
G1
G2G2
G2