www.excalibur-fire.com P95-3 Zero Clearance Direct Vent Gas Fireplace MODELS: P95-NG3 Natural Gas Owners & Installation Manual P95-LP3 Propane WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your FOR YOUR SAFETY building.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Excalibur® Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P95-3 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P95-3 has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS SAFETY LABEL MA Code - CO Detector (for state of Massachusetts only) ..................................5 Log Set Installation ......................................................27 Glass Door Installation ................................................29 Front Facade ...............................................................29 Optional Screen Doors ................................................29 Accent Kit Installation ..................................................
SAFETY LABEL This is a copy of the label that accompanies each P95-3 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. Copy of Safety Decal for P95-3 NOTE: Excalibur® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The P95-NG3 or P95-LP3 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturer's instructions and all applicable codes.
INSTALLATION LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your fireplace, ensure that the clearances outlined on this page are met. MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r servicing. 1) Ensure that structural members are not cut or weakened during installation. 3) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).
INSTALLATION COMBUSTIBLE MANTELS FRAMING AND FINISHING Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagram below. 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1" (32mm) thick.
Facing Over 1" (25mm) Thick Header 11” dia. hole through wall for Flex or for DuraVent If the facing material is over 1" (25mm) thick (example: brick or river rock), install the facing around the perimeter of the face. You may wish to make a face template as shown on the diagram. 48-3/4” CL 2" F P I o ff e r s a c o v e r plate template. See the "Optional Cover Plate Template" section. 53-3/4” 4) Note: The unit does not have to be completely enclosed in a chase.
INSTALLATION OPTIONAL COVER PLATE TEMPLATE 1) Ensure top clip screws are at top of oblong holes before installation. Oblong Screw Holes UNIT ASSEMBLY PRIOR TO INSTALLATION The 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position. Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace top.
INSTALLATION VENTING FPI Direct Vent System Flex Horizontal Terminations Only These venting systems, in combination with the P95-3 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator. J= Clearance to service regulator vent outlet *(min 36"/90cm) K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm) L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m) M= Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.
INSTALLATION SIMPSON DURA-VENT VENTING The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P95-3.
INSTALLATION SIMPSON DURA-VENT VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI.
INSTALLATION VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and FPI DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o elbow (two 45o elbows equal one 90o elbow). Simpson Dura-Vent 5" inner diameter 8" outer diameter Regency® Flex Vent 5" inner diameter 8" outer diameter Note: Must use optional flue adapter (Part # 770-994) when using Simpson Dura-Vent pipe.
INSTALLATION Horizontal Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) G) V 0' Min. 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. H + H1 2' Max. 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. 8' Max. With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required. Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows.
INSTALLATION Vertical Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) V 0' Min. 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. H 2' Max. 4' Max. 5' Max. 6' Max. 7' Max. 8' Max. V + V1 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 8 feet total horizontal. Please note min. 1 foot between 90 o elbows is required.
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbow, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. • • • Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles.
INSTALLATION The P95-3 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as per the diagram. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed.
INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION Install the vent system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
INSTALLATION VERTICAL TERMINATION Diagram 5 The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings. Note: If installing termination on a siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. 7) Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble (Part # 1247) over the vent pipe.
INSTALLATION the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. 7) Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twistlocking it.
INSTALLATION P95-NG3 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #30 Max. Input Rating Min. Input Rating 45,000 Btu/h 23,200 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.8"+/- 0.2"w.c. For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1. The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
INSTALLATION CONVERSION KIT# 773-969 FROM NG TO LP FOR P95-3 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 8) Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. LPG Conversion Kit Contains: Qty.
INSTALLATION 12) Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it. WARNING! Do not overtighten the screw. Recommended to grip the wrench by the short side. Installation of the DC Sparker: 15) Locate the Piezo Ignitor situated at the side of valve. Piezo Ignitor 16) Verify that if the conversion is from NG to LPG, the screw must be reassembled with the red o-ring visible (Fig. 5).
INSTALLATION 19) Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit. 23) Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield. 27) Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit. Heat Shield 20) Locate the ground lug at the receptical box, left of the unit. 24) Plug the DC spark generator wires to the DC Sparker.
INSTALLATION OPTIONAL BRICK PANELS LOG SET INSTALLATION 1) Open the bottom louver door. Loosen the 2 screws holding the Burner ON/OFF switch and bracket to the bottom louver and lift the assembly out. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. 4) Place Log 312 on the front right side of the burner, fitting the log on the 2 pins. 312 2) Remove facade.
INSTALLATION 8) Place the top of Log 307 across the notch on Log 311. 11) Fit Log 310 on the pin and then swing the front end of the log to hit the first grate 12) Place the embers on the front of the burner tray. 306 311 307 310 311 Place embers on the burner tray. DO NOT BLOCK BURNER HOLES Notch 13) Test fire to ensure proper light off (make sure flame flows smoothly from one end of burner to the other). If there is any flame hesitation, check that area for any blockage of the burner ports.
INSTALLATION GLASS DOOR INSTALLATION 3) Mount the 2 screws back onto the mounting plate on the rear of the facade through the tab on the glass frame and then tighten screw to secure. OPTIONAL SCREEN DOORS 1) Attach door bracket to side using 2 screws to the left and right side of the unit. 1) Fit top door bracket over the flange at the top of the firebox. 2) Secure with 3 screws on the bottom. Door Bracket attaches with 2 screws. Flange Tighten both screws to secure Front Facade to Glass Door.
INSTALLATION ACCENT KIT INSTALLATION SINGLE DOOR ACCENTS 1) Remove the rivets from the surround by pulling out the hoseclamp with a screwdriver or plyer. Re-install the rivets by putting them through the holes on the sides of the surround. 4) Place the emblem over the emblem design on the surround. Insert the studs through the holes. To secure them first put on the split lock washer and then the nut and tighten. 5) Remove the 2 studs on the sides of the Hood.
INSTALLATION Option 1: REMOTE CONTROL Option 2: WALL SWITCH Option 3: WALL THERMOSTAT Use the Excalibur® Remote Control Kit approved for this unit. Use of other systems may void your warranty. 1) Run the wire through the right or left side inlet opening. Be careful not to damage wire. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan is installed at a later date.
INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed. 5) Verify that the venting and cap are unobstructed. 6) Ensure that the brick panels are installed. 7) Verify log placement.
OPERATING INSTRUCTIONS Copy of the Lighting Plate Instructions NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.
MAINTENANCE FAN MAINTENANCE Ensure that the fan blades do not rub against the valve tubing. See diagram 1. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. To Install the Fans 1) Shut the power off. 2) Open the bottom louver. Loosen the 2 screws holding the Burner ON/OFF switch and bracket to the bottom louver and lift the assembly out. 3) Remove the bottom louver by loosening the 2 hinge screws. IMPORTANT: There are 2 fans in this fireplace.
MAINTENANCE REMOVING VALVE 1) Shut the power off. 2) Open the bottom louver door. Loosen the 2 screws holding the Burner ON/OFF switch and bracket to the bottom louver and lift the assembly out. 9) Remove the front bottom brick panel by sliding it out. Then remove the back bottom brick panel by tilting it slightly up and then out. The brick panel is very fragile - handle with care. Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.
PARTS LIST P95-3 MAIN ASSEMBLY Part # 1) 2) 7) 8) 9) 10) 22) 430-129 * 910-428 910-429 910-430 904-687 770-033 Description Receptacle Box Mount Thermodisc Bracket Duplex Receptacle Box - Receptacle Cover - Receptacle Clamp Connector Baffle Guide 23) 780-011 25) 770-074 Standoff - Top Standoff 26) 27) 28) 29) 30) Sealing Plate Outer Flue Collar Inner Flue Collar Assy Flue Mounting Bracket Gasket for Flue Collar 770-128 * * * * 773-528 31) * 32) * 770-901 770-902 770-903 770-904 33) 34) 35) 36) * * *
PARTS LIST 40 Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace
PARTS LIST P95-3 BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 54) 948-043 Piezo Ignitor & Nut Bottom Relief Spring 770-574/P 770-576/P 56) 770-071 57) 910-478 Valve Assy - Natural Gas Valve Assy - Propane Gasket - Valve Tray Valve - S.I.T. - NG/LP 58) * 66) 910-038 910-039 904-660 904-431 936-170 67) 780-057 68) W840470 Valve Bracket Pilot Assy 3 way flame - S.I.T. - NG Pilot Assy 3 way flame - S.I.T.
PARTS LIST P95-3 FLUSH FRONT ACCESSORIES Part # 771-518 132) * 135) 940-328/P 136) 936-155 904-691 141) 142) 145) 146) 148) 157) Description Part # Description 790-082/10 790-082/02 155) 904-735 157) 904-722 904-722/02 904-722/10 Door Assembly - Complete Flush Door Frame Glass (Flush) Glass Gasket (Tadpole) U-Clip 770-920 770-922 770-914 770-916 770-918 Surround - Black - Complete Surround - Polished Gold - Complete Surround - Antique Gold - Complete Surround - Antique Nickel - Complete Surround - A
WARRANTY Excalibur® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Excalibur® Product.
Excalibur® fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Excalibur® Product. See the inside back cover for details. Register your Excalibur® online at http://www.excalibur-fire.