EXCELL PRECISION CO., LTD. User Manual © Excell Precision Limited 2006. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
EXCELL PRECISION CO., LTD. TABLE OF CONTENT SAFETY PRECAUTION....................................................................... 3 FEATURES AND SPECIFICATION.......................... 4 1-1 FEATURES............................................................................................................................ 4 1-2 SPECIFICATION .....................................................................................................................
EXCELL PRECISION CO., LTD. TRANSMISSION INTERFACE ............................... 24 7-1 OP-01 RS232 / RS485 SERIAL OUTPUT (WITH RTC)........................................................ 24 2 2 Pin Allocation of Rear Panel........................................................................................................................24 Connection Description (RS485) ................................................................................................................
EXCELL PRECISION CO., LTD. BEFORE USING THE INDICATOR Thanks for purchasing EXCELL FM Mini-indicator. In order to operate smoothly, to last the durability, and to reduce the chance of breakdown for this product, please read the following instructions carefully. Safety Precaution & Turn off power before installing or disassembling. & Keep the product away from sunshine. The temperature range for operation is -10℃ ~ +40℃. & To connect the ground is a must for this equipment.
EXCELL PRECISION CO., LTD. Features and Specification 1-1 Features l Large and clear LCD (height 25.
EXCELL PRECISION CO., LTD. 1-2 Specification Analog Specification ♦ ♦ ♦ ♦ ♦ Load Cell Current: DC 5V ±5% 60mA (Up to Four 350Ω Load Cells) Max. Load Cell Input Voltage: 16 mV Input Sensitivity: 0.12µV/D or more Conversion Rate: Approximately 100 times/sec. (max.) Resolution: 19 bits Digital Specification ♦ ♦ ♦ ♦ ♦ ♦ Display: LCD, 6 digits, height 25.4x10mm, LED backlight Display Frequency: 50 times/sec. (max.) Display Range: - 999999 ~ 999999 Min. Division: 1, 2, 5, 10, 20, 50 Decimal Point: 0, 0.0, 0.
EXCELL PRECISION CO., LTD. Keypad Operation Instruction Function General Function Setting Operation Description Press and hold ENTER and then press F1 , Refer to Function Parameter Setting for details Weighing Parameter Setting Adjust calibration switch to ON Setting for decimal point, capacity, division, zero tracking, and unstable detecting, etc. Refer to 5-1 Specification Setting for details.
EXCELL PRECISION CO., LTD. Front & Rear Panels 3-1 Front Panel R + - TARE ESC MOTION ZERO + M+ TARE GROSS GROSS NET PT F2 F1 ENTER Indication: : : TARE : MOTION : M+ : GROSS : PT : Battery charged status Battery charging status Tare status Unstable weighing indication Accumulation status indication Gross weight Pre-tare Keypad: ESC ZERO TARE GROSS NET 3 F2 4 F1 ENTER 1) Power ON / OFF. Press and hold this key for 3 seconds to shut down. 2) To abort or escape when setting.
EXCELL PRECISION CO., LTD. 3-2 Rear Panel 1 2 5 3 4 1. Battery Case 2. RS232/485 Input/Output 3. DC 9V Power Input 4. Calibration Switch 5.
EXCELL PRECISION CO., LTD.
EXCELL PRECISION CO., LTD.
EXCELL PRECISION CO., LTD. 4-3 Battery Assembly 將多餘的電線塞入電池孔中 Stuff the surplus wires into the battery case.
EXCELL PRECISION CO., LTD. Internal Calibration Adjust calibration switch to “ON”, and the screen displays: After 2 seconds ENTER Press ZERO Press TARE ENTER ZE RO Press Press TARE ENTER Adjust calibration switch back to “OFF”.
EXCELL PRECISION CO., LTD. 5-1 Specification Setting *Parameter Code Press ENTER ⇒ Decimal Point ⇒ Capacity ⇒ Division 1 Input the *Parameter Code intended ⇒ Division 2 ⇒ Zero Tracking Setting ENTER ⇒ Unstable Detecting Setting Press The screen displays the parameters set previously. Input the parameters intended and then press ENTER . Continue other functions setting or press to escape.
EXCELL PRECISION CO., LTD. 2 Specification Parameter Description Setting Parameter Function Code Description Parameter Decimal Point CSP-00 CSP-01 CSP-02 Default Setting Refer to the description on next page. Capacity 999999 ↓ 000000 Max. value for weight display 999999 Division 1 1 2 5 10 20 50 Min. value for weight display 1 Min.
EXCELL PRECISION CO., LTD. 2 Parameter Display Description CSP-00 Decimal Point Display Decimal Point Digit None CSP-04 . 1 Digit . 2 Digits . 3 Digits . 4 Digits Zero Tracking Setting Display Division/Period 0.25 D/1 sec . 0.5 D/1 sec . 0.75 D/1 sec . 1D/1 sec 1.25 D/2 sec . 1.5 D/2 sec . 1.75 D/2 sec . 2 D/2 sec No Zero Tracking CSP-05 Unstable Detecting Setting Display Division / Period 0.25 D/1 sec . . 0.5 D/1 sec 0.75 D/1 sec . 1D/1 sec 1.25 D/2 sec . . . 1.
EXCELL PRECISION CO., LTD. 5-2 Internal Weight Calibration Turn on and warm up the machine for 15 to 30 minutes before calibration. Adjust calibration switch to “ON”, and the screen will display Press TARE or ZERO to select . .
EXCELL PRECISION CO., LTD. 2 Password Setting Adjust calibration switch to “ON” After 2 seconds ZERO F1 Input new password 4 “0000” means no password. ENTER Confirm new password (re-input again) ENTER 4 After complete password setting, when entering calibration mode or function setting mode, the screen displays for 1 second, and then . It’s necessary to input the correct password to continue each setting. If the password inputted is not correct, the screen displays FM User Manual 17 .
EXCELL PRECISION CO., LTD. 5-3 Internal Function Setting Press ENTER *Parameter Code ⇒ Tare or Zero Function under Unstable Status ⇒ Turning on Re-zero Input the *Parameter code intended ⇒ Re-zero Range ⇒ Filter Strength Press ENTER ⇒ AD Sampling Rate ⇒ Animal Scale Mode The screen displays the parameters set previously.
EXCELL PRECISION CO., LTD. 2 Internal Function Parameter Description Setting Parameter Function Code Description Parameter CFN-00 CFN-01 Default Setting Tare or Zero Function under Unstable Status 0 1 OFF Re-zeroing after Turning on 0 OFF 1 ON 0 2 ON 0 CFN-02 Re-zero Range 0% ~ 30% 0%: Full range re-zero 1% ~ 30%: Capacity × ± setting value% CFN-03 Filter Strength 0~5 Strength increases by number 0 No limit 1 20 times/sec. 2 10 times/sec. 3 0 5 times/sec.
EXCELL PRECISION CO., LTD. 2 Error Message (1) Load Cell or A/D circuit extraordinary (2) Real weighing value ≦ zero value (3) Internal resolution < 0.12μV/D range (4) .
EXCELL PRECISION CO., LTD. Special Function 6-1 Animal Scale Function Setting 2 CFN-05 = 1 (Animal Scale Mode1: No weight display under unstable status) When no any object is on the platter, the screen will display: When the object is on the platter, after weight has been measured, the screen will display: .
EXCELL PRECISION CO., LTD. 6-2 Dual Range Resolution Switch Function If the setting of CSP-02 is not the same as CSP-03, the dual range resolution will be activated.
EXCELL PRECISION CO., LTD. 6-3 Pre-tare Function 2 FNC-02 or FNC-03 setting is at parameter 6. (Pre-tare Function) Under weight display status, press screen will display: F1 or F2 4 key (according to FNC setting), the Input the pre-tare value intended Press ENTER key Back to weight display status (PT indication lights up) Pre-tare Cancellation When the gross weight is displayed as “0”, press 6-4 TARE key to cancel the pre-tare value.
EXCELL PRECISION CO., LTD. Transmission Interface 7-1 OP-01 RS232/RS485 Serial Output (with RTC) CN3 CN2 123 123 To short 1 and 2 pins is RS485 output. To short 2 and 3 pins is RS232 output. 2 Pin Allocation of Rear Panel 4 5 9 4 3 8 1 2 7 Pin Function 2 3 RXD TXD SG DA DB 5 6 7 6 RS485 interface is capable to connect up to 10 mini-indicators.
EXCELL PRECISION CO., LTD. 2 Connection Description (RS485) 終端電阻 終極電阻 Terminal Resistant Host 電腦主機 EX0419 # 1 RS - 06 = 01 EX0419 # 2 RS - 06 = 02 EX0419 # 10 RS - 06 = 10 4 Notice ♦ ♦ If the terminal resistant is built-in the host interface, it’s not necessary to connect with another one outside. If the host computer is no signal ground (SG), it’s not necessary to connect with it.
EXCELL PRECISION CO., LTD. Function Parameter Setting Under general weight display status, press F1 ENTER , and the screen will display: ENTER Press ZER O Press TARE key key ENTER Press ESC to escape. Back to general weight display status.
EXCELL PRECISION CO., LTD. 8-1 Function Setting *Parameter Code Press ⇒ Key Disable ENTER ⇒ DSP Update ⇒ F1 Key Function Setting Input the *parameter code intended ⇒ F2 Key Function Setting ⇒ Backlight Setting Press ENTER The screen displays the parameters set previously. Input the parameters intended and then press ENTER .
EXCELL PRECISION CO., LTD. 2 Function Parameter Setting Parameter Function Code FNC-00 FNC-01 Key Disable DSP Update F1 Key Function Setting FNC-02 F2 Key Function Setting FNC-03 Setting Parameter 0000 ↓ 1111 FNC-04 FM User Manual Description 0 ON 0000 is corresponding to: 1 OFF ZERO TARE GROSS NET 3 F2 4 0000 (from left to right) 0 No Limit 1 20 times/sec. 2 10 times/sec. 3 5 times/sec. 4 0 1 times/sec.
EXCELL PRECISION CO., LTD. 8-2 RS232 Setting *Parameter Code Press ENTER ⇒ Information Pattern ⇒ Transmission Method ⇒ Transmission Rate Input the *Parameter code intended ⇒ Parity, Bit Length, Stop Bit ⇒ Unstable or Over Load Press ENTER ⇒ Auto Transmission Condition ⇒ Command Address The screen displays the parameters set previously.
EXCELL PRECISION CO., LTD.
EXCELL PRECISION CO., LTD. RS1-08 Transmission Times RS1-09 Date Setting RS1-10 Time Setting FM User Manual 0 No Limit 1 1 times/sec.
EXCELL PRECISION CO., LTD. 2 Transmission Format RS1-00 ⇒ 0 ~ 3 S , T Header 1 G S , 1 + Header 2 2 3 . 4 6 5 g CR LF Weight Data ( 8 digits ) Header 1 ST : Stable Weight / US : Unstable Weight Header 2 GS : Gross Weight / NT : Net Weight / / Unit Terminators OL : Weight Over Load TR : Tare Weight Data ( 8 digits ) The first digit of weight data represents “+/-“ indication for weight value. The other 7 digits, including decimal point, represent the weight value.
EXCELL PRECISION CO., LTD.
EXCELL PRECISION CO., LTD. Maintenance 9-1 Default Recovery for All Parameters (1) Adjust the calibration switch to “ON”, when re-zeroing after turning on, press F1 ENTER and hold simultaneously. . (2) The screen will display . ENTER , and then adjust the (3) If decided, press and hold until displaying calibration switch to “OFF”. 9-2 Default Recovery for General Function Parameters (1) When re-zeroing after turning on, press .
EXCELL PRECISION CO., LTD. 9-3-1 Program Version Number 7-segment display reveals program version number. 9-3-2 7-segment Display Testing 7-segment display reveals “ 9-3-3 ~ ” and “.”. Keypad & Calibration Switch Testing Adjust calibration switch to “ON”, and press any key, the corresponding bit will be → . changed from 9-3-4 AD Conversion Value 7-segment display reveals the internal value of the present weight. 9-3-5 EEPROM Testing Displaying represents in normal condition.