Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform sched-
uled maintenance as necessary.
2. Set the On/Off switch to "Off" and unplug unit.
3. Turn the regulator counterclockwise and set the outlet pressure to zero.
4. Remove the air tool or accessory.
5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure
is approximately 20 PSI. Release safety valve ring.
6. Drain water from air tank by opening drain valve on bottom of tank.
  


7. After the water has been drained, close drain valve by turning clockwise.

If drain valve is plugged, release all air pressure. The valve can then be
removed, cleaned, then reinstalled.
8.
Protect the electrical cord and air hose from damage (such as being stepped
on or run over).
9. Store the air compressor in a clean and dry location.






  
Excessive tank
pressure - safety
valve pops off
Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.
Move On/Auto/Off lever to the "Off"
position, if the unit does not shut off
contact a Trained Service Technician.
Pressure switch "cut-out"
too high.
Contact a Trained Service Technician.
Air leaks at
fittings
Tube fittings are not tight
enough.
Tighten fittings where air can be
heard escaping. Check fittings with
soapy water solution. DO NOT OVER
TIGHTEN.
Air leaks at or
inside check
valve
Check valve seat
damaged.
A defective check valve results in
a constant air leak at the pressure
release valve when there is pressure
in the tank and the compressor is shut
off. Replace check valve. Refer the "To
Replace or Clean Check Valve" in the
Service and Adjustments section.
Air leaks at
pressure switch
release valve
Defective pressure switch
release valve.
Contact a Trained Service Technician.