EXCELL PRECISION CO., LTD © Excell Precision Limited 2005. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. SI-132 v1.
EXCELL PRECISION CO., LTD 222 CONTENT 222 BEFORE USING THE SCALE ......................................................................................... 2 PREPARING TO USE THE SCALE ................................................................................. 3 CHAPTER 1 INTRODUCTION......................................................................................... 4 1-1 FEATURES AND SPECIFICATION..................................................................... 4 1-2 SCALE APPEARANCE ...
EXCELL PRECISION CO., LTD BEFORE USING THE SCALE Thank you for purchasing an EXCELL High Precision Electronic Digital Scale. In order to use the scale properly, please read this User Manual carefully before use. If you have a problem concerning the scale, please contact your supplier. INSTRUCTION FOR USE 1) Please keep the scale in a cool dry place. Do not store it at high temperature. 2) Do not allow any liquids to come into contact with the scale. If necessary wipe the scale with a dry soft clothe.
EXCELL PRECISION CO., LTD PREPARING TO USE THE SCALE 1. Locate the scale on a firm level surface free from vibrations for accurate weight readings. 2. Adjust the four levelling feet (if fitted) to set the scale pan level using the spirit level bubble located at the front of the scale. 3. Avoid operating the scale in direct sunlight or drafts of any kind. 4.
EXCELL PRECISION CO., LTD CHAPTER 1 INTRODUCTION 1-1 FEATURES AND SPECIFICATION Features: n 30,000d display resolution n Large LCD display (digit height 8.5mm x 18.
EXCELL PRECISION CO., LTD 1-2 SCALE APPEARANCE 196 mm 174 mm 80.4 mm The package includes: 1. Scale 1 off 2. AC adaptor 1 off 3. User Manual 1 off * Stainless steel weigh pan is an optional depends on the model you purchase. When you first unseal the product package if you find any of the items above are missing, contact your supplier. 284 mm Notice: Dry batteries are not included in the product package. 213 mm 1-3 POWER SUPPLY POWER SUPPLY SELECTION 1. 4 x UM-2 1.5V dry batteries (not included) 2.
EXCELL PRECISION CO., LTD 1-4 DISPLAY HI OK LO kg lb Pcs à0ß Net 61 STABLE 62 GROSS 63 P cs 64 . . . . . . . . . . 65 Hold 66 1 2 3 4 5 6 7 : The weight on weigh pan is greater than the high limit : The weight on weigh pan is equal to the OK limit : The weight on weigh pan is lower than the check value : kg units. When “kg” is displayed, it means the weight shown is in kg : Pound units. When “lb” is displayed, it means the weight shown is lb : Piece units.
EXCELL PRECISION CO., LTD 1-5 KEYBOARD FUNCTION ON/ZERO KEY This key possesses two functions: Power On and Zero function. OFF KEY When the scale is switched on, press the OFF key, the scale will switch off. TARE KEY The tare function will not operate during the following conditions: (1) When the scale powers on if the weight is negative and after a container is placed on the weigh pan if the weight is still below zero. (2) The tare value is over the full scale capacity.
EXCELL PRECISION CO., LTD 1-6 OPERATING THE SCALE POWER ON When the scale is off, press the ON/ZERO key, the scale will switch on. POWER OFF When the scale is on, press the OFF key, the scale will switch off. ZERO When the weigh pan is empty (free of load) and the display is not showing zero, press the ON/ZERO key to zero the scale. At zero, the “à0ß” indication is on. 4 When the weight value is within the zero range, the zero function operates to zero the scale or cancel the tare function.
EXCELL PRECISION CO., LTD NET/GROSS FUNCTION In the Tare mode, the screen displays the “Net” icon, press the NET/GROSS key to switch between the “Net value” and the “Gross value”. 4 When the 6GROSS icon is on, the weight value on the display is the total amount of the tare value and net value. 4 At the Gross status, only OFF and NET/GROSS keys are functional. 4 NET/GROSS key is only used in Tare mode.
EXCELL PRECISION CO., LTD CHAPTER 2 ADVANCED FUNCTIONS 2-1 ADVANCED FUNCTION SETTING TABLE Below is an overview of the advanced functions.
EXCELL PRECISION CO., LTD DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Continuous Transmission setting Continuous data transmission rate Auto transmission at Zero Reset of auto transmission Output condition setting SI-132 v1.
EXCELL PRECISION CO., LTD 2-2 ADVANCED FUNCTION SETTING WORKFLOW In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows .
EXCELL PRECISION CO., LTD 2-3 GENERAL FUNCTION SETTING n There are 7 functions in the general function setting mode from to . Workflow of the General Function setting: DISPLAY ACTIONS NOTE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) Press TARE key TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left.
EXCELL PRECISION CO., LTD 2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode change the backlight function setting. ACTIONS DISPLAY to NOTE Press TARE key LCD displays the last status Use ON/ZERO or UNITS key to select function “on” or “off Press TARE key to go back to the Advanced function setting menu Automatic backlight function When the weight is over 10d, the display backlight will be on.
EXCELL PRECISION CO., LTD 2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode change the automatic power-off timer setting.
EXCELL PRECISION CO., LTD 2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In to set the Hi/Lo/OK values. one specific unit mode, enter ACTIONS DISPLAY NOTE 4 When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled.
EXCELL PRECISION CO., LTD 2-3-4 Restore to the Default Setting Select in the General Function setting mode restore to the default setting. ACTIONS DISPLAY to NOTE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) Press TARE key TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left.
EXCELL PRECISION CO., LTD 2-3-5 Noise Filter Setting Select in the General Function setting mode set the noise filter setting. ACTIONS 4 When modifying to NOTE DISPLAY , the parameters of remain un-altered.
EXCELL PRECISION CO., LTD 2-3-6 Hold Function Setting Select in the General Function setting mode set the hold function.
EXCELL PRECISION CO.
EXCELL PRECISION CO., LTD 2-4 WEIGHT CALIBRATION In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows use the NET/GROSS or UNITS key to select and to enter the weight calibration mode. ACTIONS NOTE DISPLAY Press TARE key kg . When the digit on the right flashes, ensure that the weigh pan is empty. Then Press the TARE key.
EXCELL PRECISION CO., LTD 2-5 RS232 SERIAL INTERFACE SETTINGS In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows use the NET/GROSS or UNITS key to select and to enter the RS232 serial interface setting mode. 4 RS232 serial interface settings span ~ , 8 settings.
EXCELL PRECISION CO., LTD 2-5-1 Baud Rate Setting Select in the RS232 serial interface setting mode to set the Baud Rate.
EXCELL PRECISION CO., LTD 2-5-2 Communication Protocol Setting Select in the RS232 serial interface setting mode to set the Communication Protocol. ACTIONS NOTE DISPLAY Press TARE key Communication protocol setting LCD shows the last setting value.
EXCELL PRECISION CO., LTD 2-5-3 Output Format Setting Select in the RS232 serial interface setting mode to set the Output Format. ACTIONS DISPLAY NOTE RS232 output format setting LCD shows the last setting.
EXCELL PRECISION CO., LTD 2-5-4 Continuous Transmission Setting Select in the RS232 serial interface setting mode to set the Continuous Transmission Setting.
EXCELL PRECISION CO., LTD 2-5-5 The selection of the Continuous Transmission Rate Select in the RS232 serial interface setting mode to set the Continuous Transmission Rate. ACTIONS NOTE DISPLAY Press TARE key Continuous transmission rate setting The LCD shows the last setting.
EXCELL PRECISION CO., LTD 2-5-6 Auto Transmission at Zero Select in the RS232 serial interface setting mode to set the Auto Transmission at Zero.
EXCELL PRECISION CO., LTD 2-5-7 Reset of Auto Transmission Select in the RS232 serial interface setting mode to Reset of Auto Transmission.
EXCELL PRECISION CO., LTD 2-5-8 Output Condition Setting Select in the RS232 serial interface setting mode to Reset of Auto Transmission. ACTIONS NOTE DISPLAY Press TARE key Output condition setting The LCD shows the last setting.
EXCELL PRECISION CO.
EXCELL PRECISION CO.
EXCELL PRECISION CO., LTD 2 Output data format Weight format Gross Net Tare Plus OL Minus OL Unstable T T T L L S S S S O O U , , , , , , G N T G G G S T R S S S , , , , , , 2 2 2 SP SP 3 3 . SP SP + 0 1 2 3 + 1 . 2 3 + 0 1 2 . + SP SP SP SP - SP SP SP SP + 0 1 2 3 4 . 3 SP SP 4 5 6 4 5 4 5 SP SP SP SP . 5 7 6 6 SP SP 6 SP t SP SP SP SP SP o l . SP k SP SP SP SP SP l z g g CR LF SP SP b Simple format G/N G/N G/N Plus OL Minus OL + 1 . + 0 1 + 0 1 + SP SP - SP SP .
EXCELL PRECISION CO., LTD APPENDIX 1 7 SEGMENT DISPLAY CHARACTERS Digit 7 segments letter Alphabet 7 segments letter Alphabet 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z SI-132 v1.
EXCELL PRECISION CO., LTD APPENDIX 2 ASCII CODE TABLE Symbol A B C D E F G H I J K L M N O P Q R S T U V W X Y Z SI-132 v1.