DC INPUTS:
REMOTE ON/OFF:
COOLING:
DCPOWERONLED:
AC OUTPUTS:
Positive (+) and Negative (-) input terminals are 5/6"
studs with brass hardware. They are accessed under the rear
cover. Use Appendix A” to choose the appropriate gauge wire for
your specific model.
Provides the user with a remote method to turn
the inverter on and off. “REMOTE” connection is on the barrier
terminal strip located under the rear cover.
Provided by a thermostatically controlled brushless fan
located on the front panel.
Locatedonthefrontpanel,willbe"ON” when
inverter is powered up, and DC power is available.
All domestic models have two NEMA - 15 outlets
(standard wall recepticle), and NEMA -Wd6 outlets (T slot, 5-20R
receptacle) on XPX. These are located on the front panel of the unit.
XP-600, XP-1100 and XP-2000 230 VAC inverters will have an
IEC-320 receptacle located on the front panel. Additionally, the unit
may be hard-wired to appliance/load using connections on the
barrier terminal strip, located under rear cover.
.
.
.
.
.
StandardFeatures
2.0
so no external current limiting devices are necessary. Exeltechs
XP-Series inverters can output their full rated power continuously
at30C(86F). Theinverterisderated20%ofits fullpowerforevery
10 C over 30 C. IE; 80% of normal capacity at 40 C, 60% at 50 C
...Etc.
.