XP125 INSTALLATION AND OPERATION MANUAL TECH 7317 Jack Newell Blvd North Fort Worth, Texas 76118-7100 817.595.4969 voice, 817.595.1290 fax 800.886.4683 toll free website www.exeltech.
XP125 INSTALLATION AND OPERATION MANUAL Copyright © 2001 Exeltech Inc. All rights reserved. This Document may not be copied, photocopied, reproduced, translated or converted to any electronic or machine-readable form in whole or in part without prior written approval of Exeltech Inc.
XP125 INSTALLATION AND OPERATION MANUAL Table of Contents Introduction 1.0 page 3 Standard Features 2.0 page 5 Installation 3.0 page 7 Operation 4.
XP125 INSTALLATION AND OPERATION MANUAL Introduction 1.0 Thank you for purchasing the finest sine-wave inverter in the power conversion industry. Exeltech's journey to excellence includes the first affordable sine wave inverter, first modular inverter system, first N+1 redundant inverter system, and the cleanest sine wave output in the industry. Exeltech strives to manufacture products of the highest possible quality, and is dedicated to 100% customer satisfaction.
XP125 INSTALLATION AND OPERATION MANUAL specify these products is in Watts (W), which is power the inverter can actually deliver. If Exeltech inverters were specified in VA, Our 1100 Watt inverter could be rated at 1375 VA at .8 power factor, 1570 VA @ .7 pf, or an incredible 2200 VA @ .5 pf. It is confusing to specify a product in VA, because the power factor must also be specified. Exeltech's XP-Series inverters can output their full rated . power continuously at 30o C (86o F).
XP125 INSTALLATION AND OPERATION MANUAL Standard Features 2.0 DC INPUTS (12 VDC - 108 VDC): a 3' non-terminated, twoconductor power cord is provided. Insulation on the negative (-) conductor is black and insulation on the positive (+) conductor . is red. AC OUTPUTS: one NEMA-15 outlet (standard wall receptacle) is . located on the Front Panel. LOW BATT / THERM BUZZER ; produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, .
XP125 INSTALLATION AND OPERATION MANUAL protected against overheating. It will provide its full rated output up to the temperature listed in the specification sheet. If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter may overheat. If the LOWBATT/ THERM buzzer sounds, immediate action is required or the inverter will shut down. Either reduce load, or provide more cooling in the immediate environment.
XP125 INSTALLATION AND OPERATION MANUAL Installation 3.0 CAUTION: It is essential to read and understand all Warnings, Cautions, and Notes before any connections are made to the Unit or System. If further assistance is needed call (817)595-4969 and ask for Customer Service. . WARNING:The inverter is designed to operate from a Battery. Performance cannot be guaranteed, and damage can result when a . charger or power supply is used without a battery in the circuit.
XP125 INSTALLATION AND OPERATION MANUAL CAUTION: Polarity of leads is critical to avoid damage to the unit or system. Check batteries and battery cables for correct polarity and . voltage. CAUTION: Observe all National and Local Electric Codes when . connecting AC Power Connections. . INSTALLATION (Location) Mounting location is critical to performance and life span of the inverter. Heat and Moisture are the two worst enemies of any electronic device.
XP125 INSTALLATION AND OPERATION MANUAL 2. Since this model has no On/Off switch, a DC Relay and external Toggle switch may be employed to turn the unit on and off. (See . Appendix “B”) 3. Disconnect the grounded (-) terminal of battery and make sure . the charger and inverter are off. 4. Make DC input connections to the inverter as illustrated in . Appendix “B”.
XP125 INSTALLATION AND OPERATION MANUAL Operation 4.0 TURN ON INVERTER: . XP-125: The inverter is on when DC input is connected and within specified range. (See “POWER INVERTER SPECIFICATIONS” sheet for operating range). . . TURN ON APPLIANCE/LOAD: 1. Check Input Power Requirements of the appliance. Make sure that it is less than Rated Output Power of the inverter.
XP125 INSTALLATION AND OPERATION MANUAL APPENDIX A Input Power Requirements: MODEL NORMAL VDC MINIMUM VDC CUT-OFF / ALARM MAXIMUM VDC RATED PEAK CURRENT CURRENT XP-125 / 12VDC 13.8 VDC 10.4 / 10.6 VDC 16.5 VDC 12.3 A 13.9 A XP-125 / 24VDC 27.6 VDC 19 / 21 VDC 33 VDC 6.1 A 7A XP-125 / 48VDC 55.2 VDC 41.5 / 42.5 VDC 62 VDC 3.1 A 3.5 A XP-125 / 66VDC 75.9 VDC 57.5 / 58.5 VDC 91 VDC 2.2 A 2.5 A XP-125 / 108VDC 124.0 VDC 94 / 95 VDC 149 VDC 1.4 A 1.
XP125 INSTALLATION AND OPERATION MANUAL APPENDIX B BAT+ & BAT- Bat+ is designated by the RED WIRE/CONNECTOR, Bat- is designated by the BLACK WIRE/CONNECTOR. Be careful . to observe proper polarity. CHAS Chassis, or EARTH GROUND. This should be connected to . the ground lug located on the front plate of the inverter. NEUT Neutral or return line of the AC output. This is internally . connected to chassis or EARTH GROUND. .
XP125 INSTALLATION AND OPERATION MANUAL Made in the USA TECH 7317 Jack Newell Blvd North Fort Worth, Texas 76118-7100 817.595.4969 voice, 817.595.1290 fax 800.886.4683 toll free website www.exeltech.com Document subject to change without notice.