User's Manual

EX7100 Technical Manual - Configuring the Terminal
©1999 Exicom Technologies (1996) Ltd 3-3 Issue 1 - May 2001
Two Exchange terminals may also be configured as a 4-wire Point to Point system. In this
mode, the system provides six, 4-wire trunked audio circuits with E & M wire control
signalling.
Subscriber Terminal Parameters (refer to Section 3.4.4)
This section explains how to check and reconfigure the operation of certain parameters,
which are specific to Subscriber terminals only.
3.4.1 Universal Parameters
Passwords.
EX7100 is protected by two levels of passwording.
The Low Level password is required to access the front panel menu system and is factory
fixed as ‘1111’. This cannot be changed by the user.
The High (or Second) Level password (required to change important operating
parameters) may be changed from the Exicom factory default setting of1234’ to any four-
digit number.
Note 1: If the high level password is changed and the new password subsequently
forgotten, you will need to contact Exicom for a backdoor password.
Note 2: It is possible to disable either/both passwords as detailed below. It
should be noted however, that disabling the passwords will allow any
unauthorised person to change the terminal’s configuration.
Changing the Second Level Password.
1) From idle, press ‘Enter’
You will be asked to enter the password.
Note
this is the First Level password
which is factory fixed at ‘1111
Use the arrow keys to enter ‘1111’, then
press ‘Enter’.
(Note: the up and down arrows increase
or decrease the number above the
symbol)
2) Use the up and down arrow keys to make
sure the
is next to Controller.
Press ‘Enter’
3) Use the up and down arrow keys to make
sure the
is next to Passwords.
Press ‘Enter’
4) Use the up and down arrow keys to make
sure the is next to Change Password.
Press ‘Enter’
Password 1
Controller
RF PARAMETERS
Set Time / date
passwords
change password
disable lo p/word