EX7100 Technical Manual - Configuring the Terminal
©1999 Exicom Technologies (1996) Ltd 3-11 Issue 1 - May 2001
Transmitter RF Power Level.
Ensure the transmitter power level is set as required. The power level is selectable in 3dB
steps (0.25W, 0.5W, 1W, and 2W for a 2Watt system, and 1.25W, 2.5W, 5W, and 10W for
a 10Watt system).
1) From idle, press ‘Enter’.
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to RF Parameters and then press
‘Enter’.
3) Use the up and down arrows until the
is
next to Tx Power and then press ‘Enter’.
4) The current Tx Power will be displayed.
Press the down key followed by ‘Enter’ to
change the power level.
8) You will be asked for the Second Level
password. Exicom’s factory default is
1234’. If the default password does not
give access, see your System Engineer as
the password may have been changed
(refer to Section 3.4.1 for details).
6) The new setting is now in effect.
Press ‘Escape’ until the display returns to
idle.
Interface Type.
Check that the terminal is set for either, G.703 (Codir or Contra), Synchronous Data,
Exchange, or Subscriber as required for connection to your external equipment. This may
be checked on the Framer menu location.
1) From idle, press ‘Enter’
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to Framer and then press ‘Enter’
3) Use the up and down arrow keys to make
sure the is next to Interface and press
‘Enter.’
Rf parameters
framer
rssi
Tx power
Tx pwr: 2.5 W
set rf level
Password 1
Rf parameters
framer
Password 1
interface
Tx Data Clock
Password 1