©1999 Exicom Technologies (1996) Ltd 4-15 Issue 1 - February 2001
Important Note:
During the BER test, the radio link will not be available to normal traffic.
Figure 4.5: End-to-End Bit Error Rate Test
Figure 4.6: Round-Trip Bit Error Rate Test
Figure 4.7: Local Interface Bit Error Rate Test
4.6.2 BER Testing an EX7100: End-to-End
A) Connect the BERT equipment to the digital interface port of both EX7100 terminals
(G.703, or Sync Data) as required.
B) Set the sending BERT equipment to provide the clocking source for the test.
C) Set the interfaces of both EX7100 terminals to match the interface of the BERT
equipment - G.703 or V.35 (sync data) - as follows:
1) From idle, press ‘Enter’
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to Framer and then press ‘Enter’
3) Use the up and down arrow keys to make
sure the is next to Interface and press
‘Enter.’
EX7100
EXICOM
o o
o o
o o
o
o
EX7100 EX7100
EXICOM
o o
o o
o o
o
o
EX7100
BERT BERT
Bit error rate
tester set to
transmit.
Bit error rate
tester set to
receive.
EX7100
EXICOM
o o
o o
o o
o
o
EX7100 EX7100
EXICOM
o o
o o
o o
o
o
EX7100
BERT
Bit error rate
tester set to
transmit and
receive.
EX7100 set for
remote loopback
EX7100
EXICOM
o o
o o
o o
o
o
EX7100
BERT
Bit error rate
tester set to
transmit and
receive.
EX7100 set for
local loopback
Password 1
Rf parameters
framer
interface
Tx Data Clock