Cleaning Your Alarm
Over time dust might collect inside your alarm, altering its performance. If this
occurs, the unit can false alarm or the WARNING icon will flash and the horn will
chirp every 30 seconds. To clean the alarm perform the following:
Remove the alarm from its bracket. If the
smoke alarm is wired to the AC power lines,
the wire harness must be disconnected.
Gently vacuum all the outside surfaces care-
fully or wipe with a clean cloth.
Locate the black smoke chamber on the back
surface of the smoke alarm.
If the WARNING icon flashing persists,
return the alarm to the manufacturer.
Twist the chamber counter-clockwise to
remove.
Carefully clean both the chamber and the
empty alarm cavity with compressed air.
With the AC wire harness reconnected (if
AC alarm type), re-install on the ceiling/wall
bracket with a clockwise twist.
Re-install the smoke chamber into the cavity
with a clockwise rotation. Align the dots on
chamber and housing to ensure a proper fit.
Press and release the Test button on the front
face to verify the alarm is still functioning
properly.
Black
Line (Hot)
Neutral
Signal
White
Red
Black
Line (Hot)
Neutral
Signal
White
Red
How to Wire and Mount the AC Powered Alarm
When installing an AC powered alarm (Model EX20AC SMK), the mounting location is
determined by the position of the electrical box that will power the alarm. Electrical
power to the box must be disconnected prior to alarm connection and
installation!
With the AC power turned off, connect
the wire harness provided with the alarm.
Connect the black wire of the harness to
the black wire(s) in the electrical box.
Typical
Circuit
End of
Line
Circuit
Align and attach the mounting bracket
with the two screws from the electrical
box. Pass the wire harness through the
center of the bracket.
Plug the wire harness into the back of the
alarm.
Press and twist the alarm clockwise into
place (see Step 4 of previous section).
Reconnect power to the AC lines of the
smoke alarm circuit. The POWER icon will
glow continuously.
Using the supplied orange wire nut, cap
the red wire(s) (not used) and push it
back inside the electrical box.
Connect the white wire of the harness to
the white wire(s) in the electrical box.
Smoke Manual with FCC and IC Statement.indd Sec1:18-Sec1:19 8/9/2013 10:39:32 AM