Complete Home Fire Protection
Single Story Homes Two Story Homes
Key
Minimum Required Smoke Alarms
Minimum Required CO Alarms
Recommended Heat Alarms
Required Interconnections
Attic
Kitchen
Living Room
Bedroom
Hall
Bedroom
Crawl Space
Attic
Bedroom
BedroomHall
Living Room
Kitchen
Utility Room
Basement
Acceptable multiLINX Alarm Spacing
Each alarm will also act as a repeating
station, so any signal received by an alarm
will be rebroadcast.
After final installation, test all alarms
for proper multiLINX radio connection.
Simply press and release the test
button of an alarm while having a
helper observe the remote alarms.
Maximum
Spacing in
Open Area
200’ (70m)
The multiLINX network communicates using
radio frequencies 905.2MHz - 911.2MHz. The
range of the radio has been tested to 200 feet
(70m) in open area distance testing.
Exigent Sensors recommends complete home fire protection. This can
be achieved by installing a combination of smoke, CO and heat alarms in
their appropriate locations in every room of the house.
Alarm Features and Functions
Power Indicator Light (Green)
On the EX20 SMK (battery-only powered), the POWER
icon will briefly flash every 30 seconds when the
alarm has been activated.
RADIO will flash once per second to indicate the
multiLINX network is open to accept additional alarms
into the network.
Radio Networking Light (Blue)
Warning Light (Yellow)
WARNING will flash yellow every 30 seconds,
accompanied by the horn chip to indicate the smoke
chamber needs to be removed and cleaned.
FIRE will flash when the alarm detects sufficient
quantities of smoke or heat. This is accompanied by the
sounding of the horn.
FIRE will stay on continuously if the alarm was triggered
remotely by another alarm on the multiLINX network.
Fire Warning Light (Red)
RADIO will cease to flash one minute after the last alarm
has been added to the network or immediately after the
button has been pressed.
On the EX20-AC SMK (AC with battery backup), the
POWER icon will run continuously while AC powered.
FIRE will continue to flash twice per minute (without the
horn) for three days after exiting an alarm condition, or
until the front button has been pressed and released.
WARNING can also be activated by a remote signal
from a CO Alarm. In this case, WARNING will be
solid red accompanied by 4 beeps of the horn.
Warning Light (Red)
WARNING will flash red every 30 seconds
accompanied by the horn chirp, for a minimum of 7
days, to indicate Low Battery. Replace the alarm.
WARNING will double flash red every 30 seconds
accompanied by the horn chirp, to indicate that the
alarm’s smoke sensor has reached its End-of-Life.
Replace the alarm.