The “Use external plot” mode:
1. In this mode, it is assumed that the user has already had an output image of known
nominal length and also measured the actual length of the image. The nominal ideal
length of 36.000” is first displayed on the front panel. The user may use the PARM+
or PARM- key to enter the ideal length digit by digit. Use the ENTER key to move
the pointing cursor to the digit to be entered.
2. Then the user may enter the actual measured length digit by digit, similar to step 1, and
use the ENTER key to move the pointing cursor to the next digit.
3. After entering the last digit, press the ENTER key.
4. If the user has entered an incorrect number carelessly, press the PARM+ or PARM-
key to restart the process of entering the measured length. After the correct number is
entered, press the ENTER key.
5. After the measured length is entered, the TechSetter will adjust its internal platen
accuracy parameter and save it in the nonvolatile memory.
6. The user may repeat the PLOT CALIBRATION test to confirm the corrected result, or
to perform one more round of adjustment if necessary.