User Guide

Maintenance
in-lb)torque.Wipeupanyexcessoilontheframe
(Figure20).
Note:Disposeoftheusedoilatarecycling
center.
9.Applyathinlmofcleanoiltotherubbergasket
onthenewlter.
10.Installthereplacementoilltertothemounting
pad.Turntheoillterclockwiseuntiltherubber
gasketcontactsthepad,thentightenthelteran
additional1/2to3/4turn(
Figure21).
11.Slowlypourapproximately80%ofthespecied
oilintothellertube—useoilrecommendedin
theEngineOwner’sManual.
12.Installtheoilllcap/dipstickandpushrmly
intoplace.
13.Checktheoillevel(Figure19);refertoChecking
theOilLevel.
14.Slowlyaddadditionaloiltobringittothefull
mark.DoNotoverll.
15.Installtheoilllcap/dipstickandpushrmly
intoplace.
16.Starttheengineandcheckforleaks.
CheckingtheHydraulicOil
Level
ServiceInterval:Beforeeachuseordaily
CheckexpansiontankandifnecessaryaddExmark
PremiumHydrooiltotheFULLCOLDline.
Figure22
1.Engine2.Expansiontank
ChangetheHydraulic
SystemFilter
ServiceInterval:Aftertherst100hours
Every500hoursthereafter
(Every250hoursifusing
Mobil115W50)
1.Stopengine,waitforallmovingpartstostop,and
allowenginetocool.Removekeyandengage
parkingbrake.
2.Locatethetwoltersunderthetransmissions.
Removelterguards.
3.Carefullycleanareaaroundlters.Itisimportant
thatnodirtorcontaminationenterhydraulic
system.
4.Unscrewlterstoremoveandallowoiltodrain
fromdrivesystem.
Important:Beforereinstallingnewlters,
applyathincoatofExmarkPremiumHydro
oilonthesurfaceoftheltersrubberseal.
Turntheltersclockwiseuntilrubberseal
contactsthelteradapterthentightenthelter
anadditional3/4to1fullturn.
5.Removetheventplugoneachtransmissionand
llthroughexpansionreservoir,whenoilcomes
outofventreinstallplug.
ExmarkPremiumHydroOilisrecommended.
Refertothechartforanacceptablealternative:
HydroOil
ChangeInterval
ExmarkPremiumHydro
Oil(Preferred)
500Hours
Mobil115W50
250Hours
Torqueplugsto180in-lb(244N-m).Continueto
addoiluntilitreachestheFULLCOLDlineon
theexpansionreservoir.
33