Troubleshooting
Problem Possible Cause Prevention/Cure
Burner will
not light using
igniter
LP gas tank valve is closed
Make sure regulator is securely attached to the LP gas tank
per “Installing LP Gas Tank,” then turn LP gas tank valve to
“OPEN”
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leakage
Turn LP gas tank valve to “CLOSED”
Wait 5 minutes for gas to clear
Follow “Checking for Leaks” section
Wires or electrode covered with cooking residue
Clean wire and/or electrode with rubbing alcohol
Electrode and burners are wet Wipe dry with cloth
Electrode cracked/broken - sparks at crack Replacement part(s) may be needed
Wire loose or disconnected Reconnect wire or replacement part(s) may be needed
Wire is shorting (sparking) between ignitor and electrode Replacement part(s) may be needed
Bad igniter Replacement part(s) may be needed
Burner will
not light with
match
No gas flow
Check if LP gas tank is empty
A. If empty, exchange, refill or replace LP gas tank
B. If LP gas tank is not empty, refer to “Sudden drop in gas
flow or reduced flame height” (see below)
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas
Turn LP gas tank valve to “CLOSED”
Wait 5 minutes for gas to clear
Follow “Checking for Leaks” section
Coupling nut and regulator not fully connected
Turn the coupling nut about one-half to three-quarters
additional turn until solid stop. Tighten by hand only - do NOT
use tools
Obstruction of gas flow
Clear burner/venturi tube
Check for bent or kinked hose
Disengagement of burner to valve Reengage burner and valve
Spider webs or insect nest in venturi Clean burner/venturi tube
Burner ports clogged or blocked Clean burner ports
Sudden drop
in gas flow or
reduced flame
height
Out of gas Exchange, refill or replace LP gas tank
Overfilling prevention device may have been activated
1. Turn control knobs to
OFF”
2. Wait 30 seconds and light grill
3. If flames are still too low, reset the overfilling prevention
device:
a. Turn control knob(s) OFF”
b. Turn LP gas tank valve to “CLOSED”
c. Disconnect regulator
d. Turn control knobs to
(HIGH)
e. Wait 1 minute
f. Turn control knobs to OFF”
g. Reconnect regulator and leak check connections,
being careful not to fully open valve
h. Light grill per “Lighting” section
Irregular flame
pattern, flame
does not run
the full length
of burner
Burner ports are clogged or blocked Clean burner ports
Flame is yellow
or orange
New burner may have residual manufacturing oils
Burn grill for 15 minutes on
(HIGH) with the lid closed
Spider webs or insect nest in venturi Clean venturi
Food residue, grease, etc. on burners Clean burner
Poor alignment of valve to burner/venturi tube Ensure burner/venturi tube is properly engaged with valve
Flame goes out
High or gusting winds Do not use grill in high winds
Low on LP Gas Exchange, refill or replace LP gas tank
Overfilling prevention device may have been activated
Refer to “Sudden drop in gas flow or reduced flame height”
(see above)