SDS

Page: 3/11
Safety Data Sheet
acc. to OSHA HCS (29 CFR 1910.1200) and WHMIS 2015 regulations
Printing date: 11/04/2016 Revision: 11/04/2016
Trade name:
ExperTexture Wall
(Cont'd. of page 2)
43.0
·
Indication of any immediate medical attention and special treatment needed:
Later observation for pneumonia and pulmonary edema.
5 Fire-fighting measures
·
Extinguishing media
·
Suitable extinguishing agents:
Water fog / haze
Foam
Carbon dioxide
Gaseous extinguishing agents
Fire-extinguishing powder
·
For safety reasons unsuitable extinguishing agents:
Water stream.
·
Special hazards arising from the substance or mixture
Formation of toxic gases is possible during heating or in case of fire.
Danger of receptacles bursting because of high vapor pressure if heated.
·
Advice for firefighters
·
Protective equipment:
Wear self-contained respiratory protective device.
Wear fully protective suit.
·
Additional information:
Eliminate all ignition sources if safe to do so.
If aerosols are bursting, stay clear until safe. Aerosol containers can be projectiles when bursting.
Cool endangered containers with water fog.
6 Accidental release measures
·
Personal precautions, protective equipment and emergency procedures
Ensure adequate ventilation.
Use personal protective equipment as required.
Keep away from ignition sources.
Protect from heat.
If containers are leaking, use respiratory protective device against the effects of fumes/dust/aerosol.
·
Environmental precautions
Avoid release to the environment.
·
Methods and material for containment and cleaning up
Absorb liquid components with liquid-binding material.
Allow gas to dissipate.
Send for recovery or disposal in suitable receptacles.
·
Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.