Installation Manual

26 27
Rearting The Syem
1. Fully open the Feed Water Adapter Valve, Cold Water Supply (page 14 and 15), and the Tank Valve. (page 22)
2. Open the RO Faucet handle and fully empty the tank before turning the Faucet handle o.
3. Let the syem rell with water (this takes 2-3 hours). You can open the RO Faucet briey to release any air
trapped inside the syem while it’s lling. (Be sure to check for new leaks during the r 24 hours after
rearting.)
4. After the Water Storage Tank has lled drain the entire syem by opening the RO Faucet until the water
ow is reduced to a slow trickle. Then close the Faucet.
5. Repeat eps 3 and 4 three times to fully ush the syem (6-9 hours)
NOTE! If the RO Syem is connected to a refrigerator do not drain the syem through the refrigerator
water dispenser. The excess carbon nes from the new carbon lter will clog the internal fridge lter.
How to Sanitize your RO Syem
(Recommended Once a Year)
1. Before you begin you will need a new Sediment Filter, GAC Filter, Carbon Block Filter, RO Membrane, Inline
Po Carbon Filter, and the Filter Housing Wrench. We also sugge using a bucket or bin large enough for the
syem to sit in (the syem will release a lot of water when it is disassembled).
2. Close any incoming water (Feed Water Adapter Valve page 15).
3. Open the RO Faucet handle and drain the syem completely (wait until water ow ops completely), then
close the Faucet handle.
4. Use the Filter Housing Wrench to open the Filter Housings, then remove and dispose of ONLY the
following lter cartridges: Sediment Filter, GAC Filter, Carbon Block Filter, and RO Membrane
NOTE! Leave the Inline Po Carbon Filter and Alkaline Filter in place! You will replace it after sanitizing
the syem.
5. Mix 1 gallon of water with 2 tbsp of household bleach. Do not add bleach directly to the lter housing.
6. Fill up the Pre Filter Housings (Sediment, GAC, and Carbon Block Housings) with your mixed solution and
close the housings using your Filter Housing Wrench.
7. Open the incoming water to the syem (Feed Water Adapter Valve page 15) and let it run for 10 minutes.
8. Open the RO Faucet handle and let it drain for 10 minutes.
9. Close the RO Faucet handle and wait for 10 minutes then open the Faucet handle again and wait for it to drain
completely. (If you smell bleach from your RO Faucet repeat eps 7-9)
10. You are now ready to replace all lters and reart your syem. Please refer to page 25 and 26 for
detailed inructions, ignore any additional sanitation eps therein.
How to Change the Alkaline Filter
(Recommended about every 6 months)
NOTE! Make sure you have shut down the RO Syem
(Step 2 in the lter change section).
1. Fir disconnect the Stem Elbows from each side of the Alkaline Filter.
2. Note the orientation of the old lter, inall the new lter in the same orientation. Remove the old lter
from its holding clips and discard it. Then, insert the new lter into the holding clips and connect the Stem
Elbows to the new Alkaline Filter (check page 12 for layout). If this is the only/la lter you are replacing
continue to the Rearting the Syem section on Page 26.
Troubleshooting
Note! Turn o the syem before servicing or inspecting
Vacation Mode
When you plan to not use your RO Syem for 2 weeks or more it should be Turned O. Locate the red
Feed Water Adapter Valve connected to your Cold Water Supply (refer to page 15).
Turn O Syem: Turn the red Feed Water Adapter Valve to point away from the Red Tubing connection
(in the Closed position, page 15) to close the water supply to the syem.
Turn On Syem: Turn the red Feed Water Adapter Valve to point towards the Red Tubing connection
(in the Open position, page 15) to open the water supply to the syem.